CONNECTING THE FEEDER CABLE
126 EX 339
mod.
To connect the feeder cable to the cook-
er it is necessary to:
– Remove the two screws that hold
shield A behind the cooker. (Fig.
11.3).
– Open completely the cable clamp D.
– Fitted with a 5-pole terminal block,
position the U bolts onto terminal
block 'B' (fig. 11.3) according to the
diagrams in figs. 11.4 - 11.5.
– Feed the supply cable through the cable
clamp "D". The supply cable must be of
a suitable size for the current require-
ments of the appliance; see the section
"Feeder cable section"
– Connect the phase and earth cables
to terminal B according figure 11.4
and 11.5.
– Pull the feeder cable and block it with
the cable clamp D
– Re-mount shield A.
N.B. Earth cable must be 3 cm longer
than neutral and live cables.
D
Fig. 11.3
62
All manuals and user guides at all-guides.com
B
A
FEEDEER CABLE SECTION
"TYPE H05RR-F"
230 V - 240 V
230 V3 - 240 V3
400 V 3N - 415 V 3N
400 V 2N - 415 V 2N
(**) – Connection with wall box connection.
– Contemporaneity factor applied
230 V - 240 V
1 2 3 4 5
L
1
230 V3 - 240 V3
1 2 3 4 5
L
1
400 V 3N - 415 V 3N
1 2 3 4 5
L
L
1
2
400 V 2N - 415 V 2N
1 2 3 4 5
L
1
2
3 x 6 mm
(**)
2
4 x 4 mm
(**)
2
5 x 2,5 mm
(**)
2
4 x 4 mm
(**)
N (L
)
PE
2
L
L
PE
2
3
L
N
PE
3
L
N
PE
2
Fig. 11.4