MWE-650-4DSM.book Seite 41 Dienstag, 16. Mai 2006 4:42 16
All manuals and user guides at all-guides.com
MagicWatch MWE650
7

Testing functions

Conduct the functional test as follows:
➤ Switch on the ignition and engage reverse gear.
✓ The numerical display shows the distance to an obstacle if there is one
within the detection range of 2,5 m.
Be very careful when you first operate the device, and make sure you get to
know the various sequences of beeps.
Zone Description (see fig. 5, page 5)
1
From a distance of around 2,5 m, (meas-
ured from the sensor), MagicWatch
detects any obstacles and indicates them
in the display. The blue LED lights up.
2
From a distance of around 1.5 m (meas-
ured from the sensor), MagicWatch signals
obstacles with a series of slow beeps from
the piezoelectronic speaker. The green or
yellow LEDs light up.
3
From a distance of around 0.95 m
(measured from the sensor)
MAGIC WATCH switches to the medium
sequence. The yellow or red LEDs light up.
4
At a distance of around 0.4 m (measured
from the sensor) and below, MagicWatch
switches to the continuous tone. The
round red LED lights up. When you reach
this zone, stop the vehicle.
Otherwise you might damage the vehicle
or the obstacle.
In Zone 4 it can occur that obstacles are not detected, because
they are no longer within range of the sensors (depending on
design).
The device is equipped with a diagnostic function: If the sensors are defec-
tive, you will hear three short beeps when you engage reverse gear.
Testing functions
Sound sequence
Beep
Beep
Beep
Beep
Beep Beep Beep
Beep Beep Beep
Beeeeep...