GYS EXAGON 400 CC Mode D'emploi page 19

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Ø electrode (mm)
1.6
2.0
2.5
3.15
4.0
5
6.3
ARCFORCE SETTINGS
It is recommended to set the arc force in median position (0) to start the welding and adjust it according to the results and welding preferences.
Note : the arcforce setting range is specific to the selected electrode type.
ADVANCED SETTINGS
Refer to the chapter « menu access » for more details regarding welding parameters.
The two MMA modes
and
: HotStart, level of the extra current at arc strike, expressed in percentage of the welding current.
: Hotstart Time, duration of the extra current at arc strike, expressed in seconds.
: Antisticking, active (On), the current will stop after 2 consecutive seconds of short circuit, inactive (Off), the current will not stop, even in
the event of long short circuit.
In MMA vertical up mode
, two extra settings are available :
: Frequency, determines the number of pulses per second (Hz).
: Percentage, determines the background/cold current expressed in percentage of the welding current.
TUNGSTEN ELECTRODE WELDING WITH INERT GAS (TIG
CONNECTIONS AND RECOMMENDATIONS
TIG welding requires a torch as well as a gas bottle equipped with a regulator.
Connect the earth clamp to the positive connector (+).
Connect the torch's earth cable to the negative plug (–).
Connect the torch's gas hose to the regulator's output.
Ensure that the torch is equipped and ready to weld, and that the consumables (Vise grip, ceramic gas nozzle, collet and collet body) are not damaged.
MODE SELECTION
Press the button
several times until the LED light switches on below the
symbol
.
WELDING STETTINGS
1. Welding intensity settings :
Adjust the welding current using the main knob
meter and the type of assembly to be carried out. The current setpoint is
indicated on the right side display.
2. Welding downslope settings :
Adjust the downslope duration using the secondary knob
tor shows the chosen settings, the right display indicates the precise downs-
lope duration in seconds.
ARC STRIKE / IGNITION :
LIFT start : Using the torch, make contact between the electrode and the metal piece, then slightly lift the electrode to start the arc.
WELD STOP / SWITCHING TO DOWNSLOPE :
To stop the weld, slightly lift the torch, the intensity will gradually reduce (downslope).
EXAGON 400 CC/CV
Rutile E6013 (A)
30-60
50-70
60-100
80-150
100-200
150-290
200-385
come with the following additional settings :
according to the dia-
. The indica-
Basic E7018 (A)
30-55
50-80
80-110
90-140
125-210
200-260
220-340
)
VRD
V
0
ARC FORCE
INDUCTANCE
-9
The grey areas are not useful for this mode.
EN
Cellulosic E6010 (A)
-
-
60-75
85-90
120-160
110-170
-
M A D E I N F R A N C E
MMA
MIG
TIG
Gouging
A
press 3 s
Basic
7018
CV
Rutile
6013
MODE
Cellulosic
6010
press 3s
press 3s
setup
+9
memory
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Exagon 400 cv