Withdrawing access rights from all user keys
If an user key is lost and should no longer retain its access rights, the
access rights of all user keys must be withdrawn at the DT 100. After this,
all the remaining user keys that are to have access rights assigned to
them must be retrained.
1. Present the red programming DELETE key to the front of the display of
the Basis DT 100. The red LED blinks.
2. Present the green programming ADD key to the front of the display of
the DT 100. The red LED lights up briefly. The access rights of all the
user keys have been withdrawn.
3. All those keys that are to retain access rights must be re-trained
access rights.
Operation
Opening the DT 100
Present a user key with access rights a few centimeters from the DT 100.
The green LED lights up, the red LED goes out. The coupling of the door
lever engages and the door can now be opened.
If the LEDs do not switch from red to green:
Ö Present the user key closer to the DT 100.
If the red LED goes out without the door opening:
The user key does not have access rights.
Ö Open the DT 100 with an user key with access rights.
After approximately 3 seconds the DT 100 closes automatically;
the door lever is uncoupled.
If the automatic closing mode (uncoupling of the door lever) is to be
changed:
Ö Contact a Dialock technician.
60
DT 100 - Status: 08.2011 - 732.29.137