left-facing door lever
3. Using a hammer, lightly tap a 3 x 22 pin into the drilled hole labelled
"L" on the back of the mounting plate. The spring of the door lever is
under pressure.
4. Insert a 4 x 22 pin in the drilled hole labelled "L45°" on the back of the
mounting plate for the door lever limit.
If the door lever angle of rotation is to be greater than 45°:
Ö Insert a 4 x 22 pin in the drilled hole labelled "L80°" on the back of
the mounting plate.
5. Secure the pins with the adhesive labels so that they do not fall out.