TROUBLESHOOTING
Error code
Description
"Buzzer sounds on
The hood command
switching on.
No error code
does not work
displayed"
Continuous sensor
ER03
activation. TC turns off
after 10 sec.
ER20
TC internal error
Overheating.
ER21
Faulty button
assessment. The user
ER22
interface switches off
after 3.5 - 7.5 seconds.
There is an
inconsistency in the
ER31
configuration of TC and
induction.
TC internal error
ER36
Communication error
between TC and
ER47
induction
Cooking area sensor
E2
overheats. TC turns off
after 10 sec.
Wrong pan.
The cooking areas
E3
are Off.
Configuration error. The
cooking area cannot be
E4
activated.
No communication
between UI and
E5
induction generator.
The cooking area cannot
be activated
FMA 839 HI
Error codes
Possible cause of the
error
LIN cable damaged or badly
connected to the hood
electronic board
Water or pan on glass, on
sensors or on control.
-
The temperature control
has detected a temperature
higher than 85° C.
-
The generator configuration
data do not coincide with
those of the TC.
-
LIN cable damaged.
There is no power supply in
the LIN cable.
Pan empty
The pans are losing their
magnetic characteristics
Internal error in generator
circuits
The induction module is not
configured yet.
LIN cable or power cable
faulty.
Internal error in generator or
filter circuits.
– 25 –
Solution
Check connection/replace the LIN cable
Clean the surface of the control. Remove
the objects from the sensors.
Replace TC.
Leave the hob to cool down and the error
will disappear when the temperature is
below 75° C.
Check the thermal insulation.
Replace TC
New configuration.
Replace TC.
Change the generator.
Replace TC.
Replace the Cable.
Check that the Cable has been inserted
properly.
Do not heat empty pans.
Use appropriate pans
Replace the module
Perform manual configuration.
Check the cables and the power supply
voltage.
Replace the module.
EN