Please Read
Immediately

1.1 Important Information

ATTENTION!
Any work on the heat pump may only be performed by authorised and
qualified after-sales service technicians.
ATTENTION!
Devices with 6kg refrigerant or more must be leak-proof tested yearly
according to ES842/2006.
ATTENTION!
The well water must comply with the required water quality standards.
ATTENTION!
The cover cannot be painted.
ATTENTION!
The heat pump is not secured to the wooden pallet.
ATTENTION!
The heat pump must not be tilted more than 45° (in any direction).
ATTENTION!
Flush the heating system prior to connecting the heat pump.
ATTENTION!
Observe that the rotary field rotates in a clockwise direction when
connecting the mains cables. (If the rotary field is not clockwise, the heat
pump will not work properly and will be very noisy).
ATTENTION!
Start-up must be performed in accordance with the installation and
operating instructions of the heat pump controller.
ATTENTION!
We recommend the installation of a suitable corrosion protection system
to prevent the formation of deposits (e.g. rust) in the condenser of the
heat pump.
ATTENTION!
Disconnect all electrical circuits from the power source prior to opening
the device.
E-2
All manuals and user guides at all-guides.com

1.2 Intended Use

This device is only intended for use as specified by the manufac-
turer. Any other use beyond that intended by the manufacturer is
prohibited. This requires the user to abide by the manufacturers
product information. Please refrain from tampering with or alter-
ing the device.
1.3 Legal Regulations and
This heat pump conforms to all relevant DIN/VDE regulations
and EU directives. Refer to the EC Declaration of Conformity in
the appendix for details.
The heat pump must be connected to the power supply in com-
pliance with all relevant VDE, EN and IEC standards. Any further
connection requirements stipulated by local utility companies
must also be observed.
The heat pump is to be connected to the heat source system and
the heating system in accordance with all applicable regulations.
Any work on the heat pump may only be performed by authorised and
qualified after-sales service technicians.
Devices with 6kg refrigerant or more must be leak-proof tested yearly
according to ES842/2006.
More information is available in the chapter Care / Cleaning.
1.4 Energy-Efficient Use of the
By operating this heat pump you are helping to protect our envi-
ronment. Both the heating system and the heat source must be
properly designed and dimensioned to ensure efficient operation.
It is particularly important to keep water flow temperatures as low
as possible. All connected heat consumers should therefore be
suitable for low flow temperatures. Raising the heating water
temperature by 1 K corresponds to an increase in electrical en-
ergy consumption of approx. 2.5%. Low-temperature heating
systems with flow temperatures between 30 °C and 50 °C are
particularly well-suited for energy-efficient operation.
Directives
ATTENTION!
ATTENTION!
Heat Pump