Nordpeis Finse Manuel D'installation page 5

Masquer les pouces Voir aussi pour Finse:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Finse
Insert
NI-25
Steel chimney
Can be installed with steel chimney
Weight included insert
Finse with wooden shelf
Finse high with wooden shelf
Safety distances (FIG 1)
Ensure that the safety distances are complied with.
Please note that these safety distances can vary from
country to country.
A
The distance from the glass in the door to a lateral
wall sideways, must be of at least 800 mm.
B
The distance between the top of the convection air
outlet and roof of inflammable material must be at least
500 mm.
The distance to any inflammable material in front of the
opening of the insert must be of at least 1 m.
*The illustration indicates the approximate center height
of the hole for the flue. As the flue is inclining, this height
will vary depending on where the surround is installed.
Distortions in floors and walls may also influence the
height. Dry stack the fireplace until the mantelpiece
element for accurate height and positioning of the
flue/chimney connection. If a fresh air supply set
is connected through the floor, mark where the hole
should be.
Finse High: ** It is necessary to have a gap of about
20 mm between the top of the surround and a roof of
combustible material.
Assembly instructions (FIG 2 - FIG 17)
FIG 3: In case of inflammable flooring, the area inside
the insert needs to be covered by a steel plate that is
at least 0,9 mm thick. Place the insert as shown and
connect the flue to the chimney.
497 kg
Place the bottom element in 90º relative to the chimney/
527 kg
wall. If needed, adjust with wedges or powder glue.
FIG 5: Make sure there is a gap between the insert and
the surround as the insert expand with heat. Also read
the section about adjustment.
FIG 9: The distance bumps on the protection shelf
ensure necessary air circulation under the wooden
mantelpiece.
In order to avoid scratches when the top element is
mounted, protect the wooden shelf with cardboard,
which is then removed when the element is in position.
FIG 17: The ridge between the upper and the lower
hood is strengthened with a strip of glass fibre that has
been soaked in powder glue.
GB