Troubleshooting and Eliminating Malfunctions
Malfunction
Possible Cause
Green indicator on
Plug of the power supply not completely plugged
charger remains dark;
into the mains outlet or connection to the charge
battery can not be
cradle disconnected
charged
Mains outlet defective
Green LED indicator or charger/power supply
defective
Blower motor does not
Battery not inserted properly
start after pressing
Battery contacts contaminated, oily or corroded
against the neck-down
sleeve; charge-control
Battery is deep discharged or defective
indicator dark
Blower motor defective
Firing procedure is not
Gas cartridge empty; check contents of the gas
actuated after pressing
cartridge
down the neck-down
sleeve and pulling the
trigger; blower motor
Metering valve defective, combustion space is not
runs normal;
filled with gas
charge-control indicator
dark
Ignition device/spark plug defective
Neck-down sleeve can
Blockage due to magazine jam; fastening
not be pushed in all the
bolt/nail jammed in discharge channel
way or only partially
Neck-down sleeve and driver blade move sluggish
due to contamination
Driver blade not seated correctly behind the fas-
tening bolt
Contact arm of the neck-down sleeve warped or
defective
Magazine strip is not
Usage of incorrect magazine strips
transported further
Magazine strip/tensioning slider move sluggish
Shooting capacity
Insufficient filled combustion space or gas car-
decreases heavily or is
tridge almost empty
insufficient; fastening
Overheating due to insufficient cooling or
bolts/nails are not
air-intake
driven in completely
Compression loss in the combustion space
Test: Press neck-down sleeve against surface for
approx. 1 minute and then actuate trigger. When
no shooting procedure is actuated, compression
loss is given
DIGA WO: Depth stop incorrectly adjusted
Neck-down sleeve does
Driver blade worn or warped; piston seized due to
not return back to start-
defective piston rings; contact arm of the
ing position after a shot
neck-down sleeve warped
Exhaust openings contaminated or clogged
Tool works irregularly;
Internal electric cable interruption or loose connec-
blower motor intermits
tion
20
All manuals and user guides at all-guides.com
Corrective Action
Plug in the power supply plug properly; plug the
charge connector properly into the charge cradle
Have mains outlet check by a qualified electrician
Have charger/power supply checked by an
authorized Würth customer service agent
Take out battery and insert again until it engages
Clean the battery contacts
Charge or replace battery (see Section "Battery
and Charger")
Have tool checked by an authorized Würth cus-
tomer service agent
Remove gas cartridge and press metering valve
approx. 2 - 3 times against a firm object. Each
time a small quantity of gas should escape, other-
wise replace gas cartridge
Replace metering valve
Have tool checked by an authorized Würth cus-
tomer service agent
Clear magazine jam (see section "Clearing a
Jam")
Clean the discharge channel and the neck-down
sleeve with compressed air. DIGA CS-1: Open the
locking fixture (observe instructions!)
Clean neck-down sleeve with compressed air and
slide the driver blade upward
Have tool checked by an authorized Würth cus-
tomer service agent
Use only original Würth fastening bolts/nails
Clean magazine
Check adapter piece and gas cartridge for correct
seating or replace gas cartridge
Do not hold hand in front of lid; clean filter mat
Have tool checked by an authorized Würth cus-
tomer service agent
Correct the setting
Have tool checked by an authorized Würth cus-
tomer service agent
Clean exhaust openings
Have tool checked by an authorized Würth cus-
tomer service agent