7. Frequently asked questions, causes, and measures

The blower does not switch itself off immediately after the toggle switches (5) have been switched off:
• The AIRSTREAM ST is equipped with an extra device cool-down function. When both toggle switches (5) have
been switched off, the blower continues to run for 5 minutes and then switches itself off automatically.
The right ball valve (8) cannot be completely closed:
• The blower must continually move at least 40 l/min. for cooling, otherwise the blower can overheat. For this
reason, the right ball valve (8) may not be completely closed.
The circuit breaker (4) is triggered when the hot-air blower is turned on:
• The attached hot-air blower exceeds the max. allowable power of 16 A. Either remove a hot-air blower or reduce
the temperatures.
When setting the air volume via the left ball valve (8), the air volume on the right side changes:
• This is normal. Both air outlets are connected to the blower in parallel. The blower delivers a maximum of 200 l/min.
air. These 200 l/min. can only be supplied at one air outlet. If the second air outlet is opened, the air volume on the
first air outlet is reduced.

8. Declaration of Conformity

Leister Technologies AG, Galileo-Strasse 10, CH-6056 Kägiswil, Switzerland confirms that in the model made
available for purchase, this product fulfills the requirements of the following EU directives.
Guidelines:
Harmonized standards:
Name of the
authorized document official:
Kaegiswil, 8/31/2017

9. Disposal

Never dispose of electrical equipment with household refuse.
Electrical equipment, accessories and packagings should be subjected to environmentally friendly
recycling.
2014/30, 2014/35, 2011/65
EN 55014-1, EN 61000-6-2, EN 61000-3-2, EN 61000-3-3, EN 60335-1,
EN 60335-2-55, EN 50581
Volker Pohl, Manager Product Conformity
Bruno von Wyl, CTO
Christioph Baumgartner, GM