Télécharger Imprimer la page

Dometic CVH Serie Instructions De Montage Et De Service page 24

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47
Installing the device
!
WARNING! Explosion hazard
• Only use propane or butane gas containers with a certified pressure
reduction valve and suitable head.
• Compare the pressure information on the data plate with the pres-
sure information on the propane or butane gas containers.
• Avoid any stress on the gas pipe system during and after installation.
Observe the following instructions for the connection:
• Observe the national requirements.
• Only use a steel pipe Ø 8 x 1 mm (welded, seamless steel or stainless steel) for the
connection.
• Fasten the gas line to the side or rear wall of the surrounding furniture parts so that
no loads are placed on the actuators.
• The entire gas line must be free of stress.
1. Connect the pipes as shown (fig. 9, page 8).
2. Attach a sign above the device with the following text:
"WARNING!
When cooking, additional ventilation must be provided, for example, by
opening windows near the device.
The device must not be used as a space heater."
3. Open the gas supply.
!
WARNING! Explosion hazard
Never check for leaks with an open flame or near sources of ignition.
4. Check all connections for leaks with leak spray.
✔ There are no leaks if no bubbles form.
7.4
Connecting the device to the 12 V DC power supply
The following only applies to models with electronic ignition.
I
NOTE
The optional automatic flame supervision device (see chapter "Func-
tion" on page 23) only works if the 12 V DC power supply is connected
with correct polarity.
1. Connect the device as shown (fig. 0, page 9).
2. Add a 1 A fuse in the plus line near the battery.
24
CVH, CVC
EN

Publicité

loading