20.1.1
Grease / oil points
20.1.2
Crosstable guideways adjustment
20.1.3
Changing the fuse
If the operation indicator light (1) no longer lights up and the machine
cannot be switched on, a defective fuse may be the reason.
The fuse can be changed by unscrewing the fuse holder (2).
STORAGE
Improper storage can damage and destroy important components. Only store packed
or unpacked parts under the intended environmental
When the machine is not in use, store it in a dry, frost-proof and lockable place to prevent the
formation of rust on the one hand and to ensure that unauthorised persons and in particular
children have no access to the machine on the other hand.
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
lubricate with grease
lubricate with oil
1.
Remove all dirt from the area.
2.
Loosen the nuts.
3.
Adjust the guideways with the worm screws.
4.
Tighten the nuts again.
5.
Check the smooth movement and adjust the settings
if necessary.
Cross table X-Axis: 1
Cross table Y-Axis: 2
Milling head Z-Axis: 3
NOTE
conditions!
STORAGE
41
BF16V