Technical Data; Product Identification; Installation And Assembly - Saci E-motion Manuel D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 47

2. TECHNICAL DATA

Nominal values:
Power supply voltage (V)
Motor voltage (V)
Working frequency (Hz)
Maximum current at frequency converter output (A)
Maximum current at frequency converter input (A)
Protection rating
Limits of use:
- Minimum ambient temperature: -10ºC
- Maximum ambient temperature: +40ºC
- Variation in the supply voltage: +/- 10%

3. PRODUCT IDENTIFICATION

Product
Frequency converter power supply:
family
M=Single phase T=Three phase

4. INSTALLATION AND ASSEMBLY

Before installing the frequency converter, carefully read the whole of this manual and consult the
safety rules valid in each country.
a) Installation of the frequency converter:
- It must be installed in a well ventilated area, protected from damp and direct exposure to the sun and rain.
- Before making the electrical connections, ensure the cable used to provide power to the frequency converter is not
live.
- Carefully verify the electrical data indicated in the specifications plate of the frequency converter before
connecting the electric current.
- The electric power cables to the frequency converter, and from the frequency converter to the pump, must be of
the correct size for the nominal consumption of the motor and the length of cable required. A table with the
maximum recommended lengths according to the cross-section of the electrical cable can be found below.
E-MOTION MT2-11A
220-240 V single phase
230 V Three phase
50/60 Hz
11 A
20 A
IP 55
E - M O T I O N M T 2 - 1 1 A
Motor output:
T2=Three phase 230V T3=Three phase 400V
25
ENGLISH
E-MOTION TT3-11A
400 V Three phase
400 V Three phase
50/60 Hz
11 A
12 A
IP 55
Maximum motor
current

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E-motion mt2-11aE-motion tt3-11a

Table des Matières