In this point you must enter the nominal consumption of the motor,
increasing or decrease the value using the arrow keys and validating
with F2.
NOTE: The nominal consumption is indicated on the specifications
plate of the motor. You must choose the correct value, for example if
you connect a frequency converter MT2 select the value 230 V and for
TT3 400 V.
Use the arrow keys to enter the maximum range for the pressure of
the transducer connected.
This value is indicated on the specifications plate of the pressure
transducer, and must always be between 4 and 20 mA.
Validate this with F2.
Use the arrow keys to enter the pressure at which you want the unit to
work.
You must take great care that this value is always within the working
curve of the pump, and always try to avoid the extremes of the curve,
in other words with flows near 0 or very low pressures.
Validate this with F2.
Once you have reached this point, the frequency converter will
program itself to know when it no longer has any demand for flow and
should stop. To do this it will ask for help to understand the features of
the installation to which it is connected.
We must follow the instructions indicated on the screen exactly.
• Open propulsion: You must open the general propulsion of the
system to cause consumption of flow.
• Click on OK: Once the propulsion is fully open, accept it using F2.
Once you have pressed F2, the pump will start up