The system automatically indicates the number of frequency converters
(x) that are connected to your network. It is an indicative parameter
and cannot be modified.
With F1 you can repeat the automatic search if the value shown "x" is
different from the real value.
O K
If you perform various searches and the value still does not coincide,
there is probably a connection error in the network of frequency
F2
converters.
Before carrying out this point, you must use the graphic sign on the
pump motor to check its rotation direction, as it may be clockwise or
anti-clockwise depending on the pump model.
In this point you can see how the motor makes a sequence of slow
turns so you can easily see whether the rotation direction is correct. It
performs 6 rotation tests and stops the motor.
F2
F1 restarts the rotation test.
If the rotation direction is not correct, select NO with the arrows and
restart the test by pressing F1 to verify that the rotation direction has
been changed successfully.
Once you have verified that the rotation direction is correct, select YES
O K
and then accept it with F2.
F2
Use the arrow keys to increase or decrease the value that is blinking
and use F2 to change to the next value. The sequence of values is:
DAY → MONTH → YEAR → HOUR → MINUTES
The lower left part of the display indicates the day of the week
calculated automatically according to the date entered.
F2
When you modify the last value (minutes) you can accept the changes
by pressing F2.
NOTE: At any point of the date you can go back to the previous value
by pressing F1.
O K
F2
32