W A I T
C L O S E
P R O P U L S I O N
S L O W L Y
P R E S S
S T O P
F R E Q U E N C Y
4 3 . 5 H z
R e p e a t
F1
T H E
W I Z A R D
F I N I S H E D
S U C C E S F U L L Y
NOTE: All the data entered or calculated in the wizard can be modified later through the unit menu.
START-UP WIZARD IN SYSTEMS WITH TWO OR MORE PUMPS
In systems with two or more pumps, the start-up wizard will run in the unit that has the transducer connected, and
only that unit will indicate the first screen of the wizard. if there is more than one pump with a transducer connected,
the system will decide automatically which unit of those that have a transducer will be used to run the wizard.
Once the wizard has finished in the unit selected, the other units on the network will be fully programmed with the
same data. It will only remain to run the rotation test of its wizard and the slave pumps will have the red warning
light on and an indication on the screen of the rotation direction test. Once their rotation tests have been performed,
it will go directly to the main screen and the assembly will be fully programmed.
7
s e c
Automatic
A N D
O K
O K
F2
O K
F2
H A S
• Wait 10 seconds: It displays a ten-second countdown after which the
next step to take will be indicated.
At this point you must close the propulsion gradually (using a minimum
of 5-7 sec) until the flow consumption is zero. At this moment the
pressure of the installation must be pressure entered previously in the
wizard.
Once the propulsion has been closed and the working pressure
established, press F2 to accept.
The stop frequency calculated is indicated, this is: for the working
pressure indicated, when the pump drops below this frequency it does
not generate any flow so the motor then stops. Press F1 to return to
the initial stop frequency search screen. Accept by pressing F2.
It shows a text for a few seconds indicating that the wizard has finished
successfully before showing the main screen.