- LIGHT ON - DIMMED - CONTINOUSLY PRESS
THE KEY - BRIGHTNESS IS INVERTED IF
COMPARED TO THE PREVIOUS FUNCTION.
COLOUR TEMPERATURE SETTING
Make sure that the lights and the fan are off.
Holding down the TIMER key will turn on the light
at the previously set colour temperature.
Press and hold the Light key to change the colour
temperature.
As long as the key is kept pressed, the colour
temperature is changed from warm to cold, just
leave the Light key to select the desired colour.
Exit the colour temperature selection function by
pressing the ON/OFF key.
TIMING
As a result of the new EU65 "Energy label" and
EU66 " Ecodesign" regulations issued by the Eu-
ropean Commission, which came into force on Ja-
nuary 1st, 2015 , our products have been adapted
to comply with these new requirements.
All of the models complying with the energy
label requirements, are equipped with new
electronics including a timer device for suction
speeds control, when the air capacity exceeds
650m³/h.
Internal motor models, with maximum air capacity
higher than 650m³/h, are equipped with a timer de-
vice that automatically switches the suction speed
from 4th to 3rd speed, after 6 minutes operation.
The energy consumption of the appliance in stand
– by mode is lower than 0.5W.
MAINTENANCE
An accurate maintenance guarantees good fun-
ctioning and long-lasting performance.
Particular care is due to the grease filter. It can be
removed by following the instructions below.
For the models SLTC111 Touch Control Version:
The saturation of the filter is indicated by the
flashing speed indicators (Fig. 17C).
Press the timer button to reset.
In Mod SL116, after 30 hours of operation mode,
all speed indicators blink simultaneously to signal
the saturation of the grease filters. To reset, press
the timer button. Cleaning of the grease filter can
be done by hand or in the dishwasher.
The grease filter needs cleaning by regular hand-
washing or in dishwasher every two months at le-
ast or depending on its use.
In case the appliance is used in its filtering ver-
sion, the active coal filter needs to be periodically
replaced.
To clean the appliance, we recommend warm wa-
ter and neutral detergent, while abrasive products
should be avoided.
The power cord shall be replaced by authori-
zed staff only.
Replacement of the LED bar:
Using an appropriate tool, remove the LED bar
from its seat (refer to Fig. 18), disconnect it electro-
nically throught the appropriate connector then re-
place it with a LED bar with same characteristics.
16