Abicor Binzel XFUME ADVANCED US Mode D'emploi page 18

Système d'extraction des fumées de soudage
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11 Disassembly
Fault
No complete fume detection.
Extraction volume too low.
External extraction system does
not start.
Dust escapes from the dust collecting
drawer.
Filter cleaning does not work.
Filter clogged.
Tab. 6
Troubleshooting
11 Disassembly
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly and repair work:
• Switch off the extraction system.
• Close off the compressed air supply.
• Disconnect all electrical connections.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Check and wear your personal protective equipment.
• Persons without personal protective equipment must not remain near the extraction system when it is being
disassembled.
• The extraction system must not be cleaned using compressed air or a hammer.
To disassemble and dispose of the device, follow the steps in sections 6 and 7 in reverse order.
 6 Putting into operation on page EN- 10
 7 Operation on page EN- 13
Dispose of the components in accordance with legal regulations.
 12 Disposal on page EN- 19
EN - 18
Cause
• Clean air outlet covered.
• Compressed air not connected
properly with supplied connectors.
• Filter elements saturated.
• Extraction hose blocked.
• Extraction hose defective.
• Power supply defective.
• Electrical components defective.
• Carbon brushes defective
• Dust collecting drawer not properly
sealed.
• Dust collecting drawer full.
• Compressed air supply faulty.
• Saturated with contaminants.
xFUME ADVANCED US
Troubleshooting
• Keep the clean air outlet clear.
• Check and replace if necessary.
• Replace the filter elements.
• Clean the extraction hose.
• Replace the extraction hose.
• Check and replace if necessary.
• Check and install correctly.
• Replace seal if damaged.
• Empty the dust collecting drawer.
• Check and replace if necessary.
• Replace filter.
BAL.0814.0 • 2020-06-17

Publicité

Table des Matières
loading

Table des Matières