NOTICE
• The extraction system must be at least 1.0 m away from the wall.
• Select a location that enables a short and straight extraction hose feed and prevents it from entering the employee's
space of movement.
• Protect the components from rain and direct sunlight.
• Only use the device in dry, clean and well-ventilated rooms.
 Fig. 2 Functional description on page EN- 9
1 Position the extraction system appropriately and lock the castors (4).
6.2 Attaching the welding torch extraction hose
NOTICE
• A maximum of two fume extraction torches (1) can be connected.
1
4
1
Air intake fittings
Fig. 3
Putting into operation
1 Connect the extraction hose (4) to the air intake fittings (1) on the extraction system (2).

6.3 Attaching the compressed air hose

NOTICE
• Connect compressed air to ensure performance and proper position of the pistons.
 Fig. 5 Control elements/ports on page EN- 13
1 Screw in the compressed air connector, including the seal (included in the scope of delivery).
2 Attach the compressed air hose to the compressed air- connection (8).
BAL.0814.0 • 2020-06-17
2
3
2
Extraction system
3
6 Putting into operation
Fume extraction torch
4
Extraction hose
EN - 11