xFUME ADVANCED US
9.5 Emptying the dust collecting drawer
1
3
1
Extraction system
Fig. 9
Emptying the dust collecting drawer
1 Turn off the extraction system by setting the Device On/Off switch (4) to "Off" (Fig. 5).
2 Pull out the mains plug.
3 Loosen the screws (3) and pull out the dust collecting drawer (2).
4 Empty the dust collecting drawer (2).
5 Dispose of collected dust in accordance with local regulations (no Fig.).
12 Disposal on page EN- 19
6 Reverse the steps above to reassemble the system.
10 Troubleshooting
DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair work and modifications to the product may lead to serious injuries and damage to the device. The
product warranty will be rendered invalid if work is carried out on the product by unauthorized persons.
• Only qualified personnel are permitted to perform work on the device or system.
CAUTION
• Suitable safety measures must be taken before performing maintenance and cleaning work.
• Maintenance and cleaning work must only be carried out on the extraction system in areas with locally filtered forced
ventilation.
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• Personal protective equipment consists of protective clothing, safety goggles, a class P3 respiratory mask, protective
gloves and safety shoes.
Please observe the attached 'Warranty' document. In the event of any doubts and/or problems, please contact your retailer
or ABICOR BINZEL.
NOTICE
• Consult the documentation for the welding components.
BAL.0814.0 • 2020-06-17
2
Dust collecting drawer
10 Troubleshooting
2
3
2 screws
EN - 17