RIB PRINCE 230V REV Mode D'emploi page 20

Opérateur réversible pour portails à battant

Publicité

Les langues disponibles
  • FR

Les langues disponibles

G
B
M
ECHANICAL STOP - OPTIONAL
Optional mechanical stop to stop closing, if the gate is not fitted with a floor
stop.
M
ECHANICAL STOPPER ADJUSTMENT
To adjust the stoppers you have to follow the scheme (Fig. 8).
To set the opening limit it's enough to fix the stopper (A) in the needed
position by tightening the 8mA screw with a n. 13 key
To obtain the desired closing limit you must adjust the stopper (B)
(OPTIONAL) in the needed position and tighten it as for stopper (A).
M
AINTENANCE
To be undertaken only by specialized staff after disconnecting power supply.
Lubricate the hinges and check the oil level and thrust force generated by
the operator on the gate once a year.
Lubricate the nut screw with silicon grease every two years.
(Cod. ACG8088)