WHIRLPOOL PUMP
MOTOR WILL NOT START – CHECK FOR:
•
Check the air line between the motor and air button for connection and depress to test air signal.
•
Improper or loose connections, open switches or relays, blown circuit breakers.
•
Manually check rotation of motor shaft for free movement and obstruction.
MOTORS CUTS OUT – CHECK FOR:
•
Wiring, loose connections etc.
•
Low Voltage at motor. (Frequently caused by undersized wiring.)
•
Binding or overload. (Amperage Reading.)
MOTOR HUMS, BUT WILL NOT PRIME. –CHECK FOR:
•
Make sure all suction, discharge lines and valves are open and un-obstructed.
•
Check for correct water level.
•
Block off suction and determine if pumps develops a vacuum. If pump develops a vacuum check
discharge line for obstruction or a leak in the suction line.
•
If the pump does not develop a vacuum and the pump has the correct water level, check for proper
voltage and / or check the pump wet end for clogging or debris
AIR MASSAGE
MOTOR WILL NOT START – CHECK FOR:
•
Check the air line between the motor and air button for connection and depress to test air signal.
•
Improper or loose connections, open switches or relays, blown circuit breakers.
•
Manually check rotation of motor shaft for free movement and obstruction.
MOTORS CUTS OUT – CHECK FOR:
•
Verify if the air supply line from the blower to the manifold is connected and not obstructed.
•
Wiring, loose connections etc.
•
Low Voltage at motor. (Frequently caused by undersized wiring.)
CHROMATHERAPY LIGHTS
LIGHTS WILL NOT OPERATE – CHECK FOR:
•
Check the air line between the motor and air button for connection and depress to test air signal.
•
Wiring and /or loose connections etc
•
Improper or loose connections, open switches or relays, blown circuit breakers.
754818-100 Rev. A
TROUBLE SHOOTING GUIDELINES
24
OWNER'S MANUAL
(continued)