HYDAC International SK Serie Notice D'utilisation page 35

Accumulateurs à piston
Masquer les pouces Voir aussi pour SK Serie:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 48
7.
Disposal
DANGER
Before carrying out any work on hydraulic
accumulators, the relevant safety precautions
must be taken.
When nitrogen is released from hydraulic
accumulators in enclosed spaces, adequate
ventilation must be provided.
Risk of suffocation.
Rechargeable versions:
– Depressurise the fluid side
– Release pre-charge pressure (p
– Remove closing elements (e.g. valves/plugs)
on the gas and fluid sides
– Disassemble the hydraulic accumulator into
its constituent parts and dispose of them
according to material type
Non-re-chargeable versions:
– Depressurise the fluid side
– Secure the hydraulic accumulator
NOTICE
When releasing the pre-charge pressure (p
on non-rechargeable hydraulic accumulators,
ear defenders, goggles and gloves must be
worn.
– By drilling open the hydraulic accumulator
on the gas side (drill bit ≤ 4 mm), release the
pre-charge pressure (p
– Dispose of the hydraulic accumulator
)
0
)
0
)
0
8.
Customer Service
Service, repeat testing and repairs can be
carried out at the HYDAC head office or at all
national and international HYDAC sales and
service centres.
Contact HYDAC head office:
HYDAC Systems & Services GmbH
Werk 13
Postfach 1251
D-66273 Sulzbach/Saar
Friedrichsthalerstr. 15
D-66540 Neunkirchen/Heinitz
Tel.:
+49 (0) 6897 / 509-01
Fax:
+49 (0) 6897 / 509-324
Internet: www.hydac.com