WARNING: THE PACKAGING MATERIAL IS NOT A
TOY. KEEP THE PLASTIC BAG OUT OF REACH OF
CHILDREN; DANGER OF SUFFOCATION!
and ship the heater. Dispose of them in compliance
with current standards.
gently using suitable devices and instruments, in
accordance with national regulations and current
standards. It can be lifted with the forklift truck, by
using suitable chains and suspension hooks (the
heater is equipped with eyebolts).
If the heater appears damaged, immediately inform
the dealer from whom it was purchased.
These heaters are equipped with handles, brackets,
supports, etc. depending on the model. These parts,
which come with the relative nuts and bolts, are in the
heater's packaging.
WARNING: THE HEATER ONLY WORKS WITH
DIESEL OR KEROSENE.
explosion hazard. Never use petrol, naphtha, solvents
Use non-toxic, anti-freeze additives in case of very low
temperatures.
It is recommended to use winter diesel oil below 5°C.
6. OPERATING PRINCIPLES
The burner pump draws the fuel from the tank and
sends it to the pressurised nozzle where it is nebulised
and mixed with comburent air in the combustion
chamber. A spark triggers combustion while the waste
fumes are expelled from the chimney. A series of
sensors constantly checks the correct operation of the
heater, stopping the cycle in the case of a fault. The fan,
located at the rear of the heater, cools the combustion
from the latter into the environment.
7. CONTROL PANEL
A. Electronic regulator.
B. Hour meter.
C. Power switch.
D. Ventilation control button.
E. Electric voltage presence light.
F. Burner block alarm light.
G. Ventilation block alarm light.
H. Overtemperature alarm light.
I. Overtemperature thermostat reset.
L. Burner connector.
M. Fuse.
N. Room thermostat remote connector.
8. OPERATION
WARNING:
CAREFULLY READ THE
INFORMATION" BEFORE SWITCHING ON THE
HEATER.
inlet and outlet connections (PIC. 4).
(PIC. 5) (SEE VOLTAGE IN THE "TECHNICAL
DATA TABLE").
If the heater does not start, refer to paragraph
"TROUBLESHOOTING".
-BUTTON ON: The ventilation works continuously
(ideal for extreme conditions of use).
-BUTTON OFF: The ventilation works automatically
(normal operation).
NOTE: IF THE HEATER SWITCHES OFF DUE TO
LACK OF FUEL, TOP UP THE TANK AND RESET
THE HEATER (SEE PAR. "RESET THE HEATER").
IMPORTANT: IN INDIRECT MODELS, COMBUSTION
PRODUCTS CAN BE DIRECTED OUTSIDE VIA
THE DUCTS. CARRY OUT THE DUCTING IN
ACCORDANCE WITH CURRENT REGULATIONS
AND
FOLLOW THE
RELEVANT SECTION OF THE MANUAL.
combustion chamber has fully cooled down. Do not pull
out the electrical plug until the cooling cycle has ended.
9. RESET THE HEATER
In the event of an anomaly during the normal operation,
To restart the heater, identify and eliminate the cause
that caused the stop (for instance, obstruction of the
it is not possible to eliminate the problem that caused
the stoppage, contact a support centre for technical
assistance.
In order to reset the heater, we recommend following the
procedure below (follow all safety-related instructions):
"SAFETY
INSTRUCTIONS
IN THE
en
it
de
es
fr
nl
pt
da