INSTALLATIoN
Appliance shutdown
13.2 Commissioning the heat pump manager
Commission the heat pump manager and make all settings in
accordance with the operating and installation instructions for
the heat pump manager.
Note
For DHW mode, ensure that the PARALLEL OPERATION
option is set in the heat pump manager. With this setting
the primary pump is also active in DHW mode.
To set the heat pump manager:
f With the MENU key, call up the main menu.
f
f Select the menu or value and confirm with OK:
f
SETTINGS
DHW
STANDARD SETTING
DHW MODE
Note
On appliances with a single phase connection, set the
heat pump manager as follows for calculating the amount
of heat.
To set the heat pump manager:
f With the MENU key, call up the main menu.
f
f Select the menu or value and confirm with OK:
f
SETTINGS
HEATING
ELECTRIC REHEATING
NUMBER OF STAGES
Area cooling setting
Material losses
!
Condensation caused by the temperature falling below
the dew point can lead to material losses. HSBC is there-
fore exclusively approved for area cooling.
Adjusting the heat pump manager settings for area cooling:
f With the MENU key, call up the main menu.
f
f Select the menu or value and confirm with OK:
f
SETTINGS
COOLING
COOLING
STANDARD SETTING
COOLING CAPACITY
ACTIVE COOLING
AREA COOLING
SET FLOW TEMPERATURE
FLOW TEMP HYSTERESIS
SET ROOM TEMPERATURE
46
| HSBC
319204_HSBC_200_de_en_fr_nl_it.indb 46
13.3 Appliance handover
f Explain the appliance function to users and familiarise them
f
f Make users aware of potential dangers.
f
f Hand over these instructions.
f
14. Appliance shutdown
Value
PARALLEL OPERA-
TION
f If you take the system out of use, set the heat pump manager
f
15. Maintenance
Value
2
Draining the buffer cylinder
Value
f Drain the buffer cylinder via the drain valve.
f
ON
system specific
ON
system specific
system specific
system specific
with its operation.
Material losses
!
Observe the temperature application limits and the min-
imum circulation volume on the heat consumer side (see
chapter "Specification / Data table").
Material losses
!
Drain the system when there is a risk of frost and the heat
pump is completely switched off (see chapter "Mainte-
nance / Draining the DHW cylinder").
to standby so that the safety functions that protect the appli-
ance (e.g. frost protection) remain active.
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
Before any work on the appliance, disconnect all poles
of the appliance from the power supply.