Installation manual e-MatriX linear 1050-1300/400 I,II,III
Ventilation
•
The e-MatriX needs a minimum free space
of 50mm above the fire.
•
The e-MatriX needs a minimum ventila-
tion of 210cm² underneath the fire.
Removing glass
5.1
Front glass
e-MatriX I:
•
Remove the cover list, see fig. 2.0a.
•
Rotate both glass clamps clockwise, see
fig. 2.0b.
•
Place suction cups and remove the front
glass see fig. 2.0c.
For replacing the glass repeat the steps in reverse
order.
e-MatriX II and e-MatriX III:
•
Rotate both glass clamps clockwise, see
fig. 2.1a and 2.1b.
•
Place suction cups and remove the front
glass, see fig. 2.1c.
For replacing the glass repeat the steps in reverse
order.
5.2
Side glass
For cleaning only it's not necessary to remove the
side glass.
•
First remove the front glass, see chapter
5.1.
•
Place a suction cup and remove the side
glass, see fig. 2.2.
For replacing the glass repeat the steps in reverse
order.
Decoration set
6.1
Fuel bed (1-piece)
See the included decoration instruction card or
Chapter 11:
➢ Please note !
Placing the logs is a meticulous job, this deter-
mines the flame distribution.
Do not let any decoration material fall into the out-
flow opening.
The outflow openings may not be completely cov-
ered.
41 <
<
<
<
• Divide the mini chips over the bottom.
• Place the logs.
• Apply the shaft material.
Fine tuning of the glow bed;
By placing the decoration chips close together you
create a real glow bed.
6.2
Pebbles / Acrylic ice
Spread an even amount of Pebbels or Acrylic-ice on
the bottom plate.
Functional test
• See "Using the appliance for the first time" in
chapter 4 of the user manual.
• Check all connections for water leaks.
• Check the operation of the extractor fan.
• Check the operation of the remote control at the
desired distance (max. 8 m).
• Check the blocking of the ITC-V2 App
• Place the decoration set, see chapter 6.
• Place the front glass, see chapter 5.1.
• Do a final functional test.