PROGRAMMING MASTER NO TOUCH 868 AND PHOTOCELLS NO TOUCH 868
A -
SETUP AND VERIFY THE CORRECT OPERATION OF THE NO TOUCH 868 PHOTOCELL
- The correct operation of the TX NO TOUCH 868 is signalled by the green DL6 which turns on
for 10 s after the insertion of the 3,6V battery.
- Press and release the S2 PROG pushbutton on the RX NO TOUCH 868 (the photocell is activated
for 3 minutes to check the alignment)
If the photocells are correctly aligned the red LED DL5 will remain turned on.
- During the 3 minutes the red LED DL5 stays on, check that when inserting an obstacle, the
red LED DL5 turns off and simultaneously the bi-colour LED DL1 on the MASTER NO TOUCH 868
turns green for the time the obstacle is inserted.
- On the MASTER NO TOUCH 868, the LED DL3 must also turn off indicating the correct exchange
of the contact on the strip or the photocell input of the control panel has occurred.
If the red LED DL5 stays off, check;
- that supports are fixed correctly;
- that on the TX NO TOUCH the position of the jumper JP4 which controls the infrared signal
range:
- is positioned on L and set to a range of 5 metres.
- is positioned on H and is set to a range of 10 metres.
B -
POWER UP MASTER NO TOUCH 868 SUPPLY
After making all connections, supply the control panel with MASTER NO TOUCH 868.
The yellow LED DL2 should be on and the buzzer should emit a sound to signal correct power
supply.
C -
PROGRAMMING PROCEDURE
Insert the batteries into the NO TOUCH circuits and position them in the internal container
already fixed to the edge of the door.
To run the set up perform the following procedure:
- Press the S1 PROG RX pushbutton which is found on the MASTER NO TOUCH 868 => the
bi-colour LED DL1 will flash red for 1 minute (time to run set up)
- Press the S2 PROG pushbutton on the safety RX NO TOUCH 868.
- On the MASTER NO TOUCH 868 the bi-colour LED DL1 changes from red to green and a buzzer
tone signals the correct security set up. At the same time the LEDs DL3 and DL4 turn on and
the control panel receives the correct safety devices signals.
ACOUSTIC SIGNALS
MASTER NO TOUCH 868 has a buzzer which signals in the installation phases and the warning
status when batteries are almost dead or alarm status in the event of failure of one of the
devices.
D -
ACCELEROMETER
The ACCELEROMETER is not compatible with automated systems equipped with gradual start
or very slow.
Stop the gradual start function or, if not possible, deactivate the ACCELEROMETER. If the door
is very slow deactivate the ACCELEROMETER.
- Verify a functional check of the installed photocell by activating the automation movement
and checking that when inserting an obstacle, in the closing door, it stops and reverses the
motion.
- In the event the door stops after starting and the alarm signals 5 BUZZER tones, this means
that the movement of the door was not detected by the ACCELEROMETER (caused by the
gradual start or by the door very slow), therefore for the correct operation of the door, it is
necessary to exclude the ACCELEROMETER.
TO DEACTIVATE THE ACCELEROMETER:
- move the JP3 jumper on the RX NO TOUCH 868 to OFF;
- press the S2 PROG pushbutton;
- the buzzer on board the MASTER NO TOUCH 868 will emit a tone for 3 s, signalling successful
deactivation of the ACCELEROMETER.
TO ACTIVATE THE ACCELEROMETER
To activate the accelerometer you need to:
- move the JP3 jumper on the RX NO TOUCH 868 to ON;
- press the S2 PROG pushbutton;
- the buzzer on board the MASTER NO TOUCH 868 will emit a tone for 3 s, signalling successful
activation of the ACCELEROMETER.
VERIFY THE CORRECT OPERATION OF THE ACCELEROMETER
- With ACCELEROMETER ACTIVE (jumper JP3 ON on the RX NO TOUCH 868) verify that when
moving the NO TOUCH 868 RECEIVER the LED DL1 turns on fixed red, the BUZZER emits 4 tones
and the LEDs DL3 and DL4 turn off for 5 s.
- After 5 s the DL1 LED will turn off and DL3-DL4 will turn on.
E -
TIME SET UP (ONLY WITH ACCELEROMETER ACTIVE - JP3 ON)
WITH THE ACCELEROMETER ACTIVE THE NECESSARY TIME STORAGE PROCEDURE IS PERFORMED.
IF THIS PROCEDURE IS NOT MADE, IT IS POSSIBLE THAT AFTER THE DOOR STARTS, THIS STOPS AND
5 BUZZER TONES ARE EMITTED.
- Press the S1 PROG RX pushbutton on the MASTER NO TOUCH 868, the LED DL1 will flash green.
- Control the door to open and close it completely at least two times consecutively.
- Wait for the green LED DL1 to turn off, or alternatively press the S1 pushbutton once to end
the procedure.
F -
SETTING UP PEDESTRIAN DOOR SECURITY (RED transmitter code ACG6202)
It is possible to set security for the pedestrian door only if you have already programmed the
NO TOUCH 868 photocell.
This security is the RED transmitter which monitors a NC contact (not supplied) installed on
the pedestrian door on the main door.
To run the set up perform the following procedure:
- position the dip switch n° 2 to ON (COMPULSORY);
- supply the RED transmitter through the batteries;
- press the S1 PROG. RX pushbutton which is found on the MASTER NO TOUCH 868: the bi-colour
LED DL1 will turn green and flash for 1 minute (time used to run set up)
- press the S2 PROG. TX pushbutton the RED transmitter: on the MASTER NO TOUCH 868 the
bi-colour LED DL1 will stop flashing green and turn off . The buzzer will emit a tone signalling
while the red LED of the RED transmitter flashes 3 times to confirm the correct set up.
VERIFY THE CORRECT OPERATION OF THE PEDESTRIAN DOOR SECURITY
Open the pedestrian door, opening NC contact connected to the RED transmitter. Verify that on
the MASTER NO TOUCH 868 the LEDs DL3 and DL4 turn off and that any door opening command
is not performed.
ANTENNA
To communicate with the safety devices, MASTER NO TOUCH 868 is equipped with a piece of
electrical wire which serves as an antenna connected to J3 terminal. If it becomes necessary
31
G
B