Télécharger Imprimer la page

GiBiDi SR2 Instructions Pour L'installation page 15

Publicité

Les langues disponibles

Les langues disponibles

SR2
F3
AUTOMATIC RECLOSING TIME
In order to enable this function and set the reclosing time, please proceed as follows:
• When the rolling shutter is closed, push SEL button for 1s (to enter in configuration mode). Then push SEL button
for 2 times until F3 PAUSE T. LED blinks.
• As the LED blinks, hold down SET button; after 1s an acoustic signal indicates the beginning of the timing. Hold
down the button for the time desired and release SET button. F3 PAUSE T. LED keeps on and an acoustic signal
indicates that the operation is successful.
• If you want to disable the automatic closure, position on F3 PAUSE T. LED and push SET button for less than 1s, as
the LED is blinking. The F3 PAUSE T. LED is off, because the function is not active any more, and the rolling shutter
has to be closed with a manual command.
WARNING: the "dead man in closing" function is incompatible with the automatic reclosing function,
therefore, enabling the dead man function, the automatic reclosing is automatically disabled; on the
contrary, to enable the automatic closing, first of all it is necessary to manually disable the dead man
function.
F4
DEAD MAN IN CLOSING
Enabling this function, the closing movement can be done only holding down the button on the transmitter or low
tension keypad for the duration of the movement. To enable this function:
• Push SEL button for 1s (to enter in configuration mode) and push SEL button 3 times until F4 MAN/CL LED blinks.
• Then push SET button for 1s until the LED keeps on and the acoustic signal indicates that the operation is
successful.
• To disable the function, repeat the procedure. In this case F4 MAN/CL LED is off, signalling that the function has
been disabled.
WARNING: the "dead man in closing" function is incompatible with the automatic reclosing function,
therefore, enabling the dead man function, the automatic reclosing is automatically disabled; on the
contrary, to enable the automatic closing, first of all it is necessary to manually disable the dead man
function.
F5
DEAD MAN IN OPENING
Enabling this function, the opening movement can be done only holding down the button on the transmitter or low
tension keypad for the duration of the movement. To enable this function:
• Push SEL button for 1s (to enter in configuration mode) and push SEL button 4 times until F5 MAN/OP LED blinks.
• Then push SET button for 1s until the LED keeps on and the acoustic signal indicates that the operation is
successful.
• To disable the function, repeat the procedure. In this case F5 MAN/OP LED is off, signalling that the function has
been disabled.
(PAUSE T. function - 4 min. max)
(MAN / CL. function)
(MAN / OP. function)
15
UK

Publicité

loading

Ce manuel est également adapté pour:

As07000