BEEP PROGRAMMING
The control unit has default BEEP active.
• To disable this function, push SEL button for 1s (to enter in configuration mode).
• Then push SEL button 5 times until F6 BEEP LED blinks.
• Then push SET button for 1s until the F6 BEEP LED is off and the acoustic signal indicates that the operation is
successful.
F7
COURTESY LIGHT SELECTION
The control unit has a 230Vac 40W max. output to connect a flashing or courtesy light.
Flashing light operation:
The 230Vac output will be intermittently active during the movement of the motor. If the automatic reclosing has been
stored, the flashing light is active also during Pause time.
Courtesy light operation:
The 230Vac output is active for 3s after a movement command.
The Courtesy light function is default enabled. If you want to enable the flashing light:
• Push SEL button for 1s on F7 FL/COUR LED (to enter in configuration mode).
• Then push SEL button 6 times until F7 FL/COUR LED blinks. Then push SET button until the F7 FL/COUR LED
is off and the acoustic signal indicates that the operation is successful.
• To restore the courtesy light mode, repeat the procedure. In this case, the F7 FL/COUR LED is on signalling the
return to courtesy light mode.
F8
LIMIT SWITCH FUNCTION
The limit switch function is default ENABLED (LED F8 ON).
In order to disable this function:
• Push SEL button for 1s (to enter in configuration mode).
• Then push SEL button until F8 LS LED blinks. Push SET for 1s until an acoustic signal indicates that the operation
is successful.
RESET OF ALL FUNCTIONS
If it is necessary to restore the default configuration, push SEL and SET buttons at the same time for 3s, until you
hear a prolonged acoustic signal.
Also the stored codes are cancelled.