This appliance may not be used in an exterior enclosed balcony, porch or entertainment area!
Read these instructions for use carefully so as to familiarize yourself with the appliance before connecting it to
1. General information
•
This appliance has been designed to be used for outdoor cooking, specifically for people who go camping to enjoy outdoor life and it
can also be used at home on your patio.
•
Various food types can be prepared on this appliance. The Safari Chef 2 is designed to utilise various cooking surfaces.
•
Gas is supplied to the unit via a hose and regulator, connected to a gas cylinder or a CADAC Power Pak. The CADAC Power Pak is a
unit that takes two or more gas cartridges. Note: hose, regulator and Power Pak are not supplied with the appliance.
•
The unit is easy to switch on, and to operate (Section 6) and the user can control the heat input with an adjustable valve.
•
The unit is supplied with a convenient carry bag.
•
This appliance complies with EN 498:2012, EN 484:2019 and SANS 1539:2017.
•
This appliance may only be used with an approved hose and regulator connected to a refillable cylinder complying with the local
regulation in force.
•
The refillable cylinder is to be used
only in an upright position. Only to be
used with a gas cylinder that does not
exceed 500mm in height and 350mm
in width (including the regulator).
•
Warning: Accessible parts may be very
hot. Keep young children away.
•
Gas appliances require ventilation for
efficient performance and to ensure
the safety of users and other persons in
close proximity, therefor do not use the
appliance in an unventilated area. It is
intended for use outdoors only.
•
Read these instructions carefully before
using the appliance.
•
Use outdoors only!
AE = United Arab Emirates
CZ = Czech Republic
FR = France
JP = Japan
PT = Portugal
SK = Slovakia
2. Safety Information
•
Do not move the appliance during use.
•
Turn off the gas supply at the gas cylinder after use.
•
The hose must be checked for wear or damage before every use and before connecting to the gas container.
•
Do not use the appliance if it has a damaged or worn hose. Replace it.
•
Do not use an appliance that is leaking, damaged or which does not operate properly.
•
This appliance must be kept away from flammable materials during use. Minimum safe distances are: Above the appliance 1.2m. At the
rear and sides 600mm.
•
Ensure that the gas container is fitted or changed outdoors, away from any sources of ignition, such as naked flames, pilots, electric fires
and away from other people.
•
Keep gas containers away from heat and flame. Do not place on a stove or any other hot surface.
•
Ensure that the assembled product is stable and does not rock.
•
In the event of light back (where the flame burns back and ignites at the jet), immediately turn off the gas supply by closing the control
valve on the gas container and then the appliance valve. After the flame is extinguished remove the regulator and check the condition of its
seal. Replace the seal, if in doubt. Re-light the appliance as described in section 6 below. Should the flame persistently light back, return
the product to your authorised CADAC repair agent.
For Outdoor use only!
its gas container. Keep these instructions for future reference.
Country of Use
Appliance Categories
Allowable gasses
Gas Pressure
Jet Number
Nominal Usage
Gross nom. heat input
Country Name and Abbreviations
AL = Albania
DE = Germany
GB = United Kingdom
KR = Korea
RO = Romania
SE = Sweden
CAUTION
IMPORTANT
6540L0, 6540L1
BE, CH, CY, CZ, ES,
FR, GB, GR, IE, IT, LT,
LU, LV, PT, SK & SI
I
3+(28-30/37)
Butane
Propane
28-30mBar
37mBar
0.65
130g/hr
1.8kW
AT = Austria
BE = Belgium
DK = Denmark
ES = Spain
GR = Greece
HR = Croatia
NL = Netherlands
NO = Norway
RU = Russia
RS = Serbia
TR = Turkey
ZA = South Africa
1 1
BE, CY, DK, EE,
FR, FI, HU, IT,
LT, NL, NO, SE,
PL
SI, SK, RO, HR,
TR, BG, IS,LU,
MT
& ZA
,
I
I
3B/P (37)
3B/P (30)
Butane, Propane or their mixture
28-30mBar
37mBar
(2.8kPa for South
Africa)
0.59
0.65
130 g/hr
130g/hr
1.8 kW
1.8kW
CH = Switzerland
FI = Finland
IT = Italy
PL = Poland
SI = Slovenia
GB
AT, CH, DE
& SK
I
3B/P (50)
50mBar
0.56
130 g/hr
1.8 kW