After a voltage drop the pump automatically starts up again with
the speed last set, or remains stopped if it had been stopped
beforehand.
Pos: 31 /Technische Dokumentation/Allgemeine Module/####halbe Leerzeile #### @ 3\mod_1437024231169_0.docx @ 36332 @ @ 1
Pos: 32 /Technische Dokumentation/Pumpendatenblatt/Motorsteuerung/Eco/Eco VS/Ein- und Ausschalten über Steuerkabel @ 8\mod_1475154370582_370.docx @ 99122 @ @ 1
The pump can be turned on and off using the control cable
(potential-free contact) intended for this purpose. This can be via
a Logic control (SPECK Pumpen) or via a small coupling relay.
This puts less stress on the electronics.
Pos: 33 /Technische Dokumentation/Allgemeine Module/#### Seitenumbruch #### @ 0\mod_1426069111812_0.docx @ 891 @ @ 1
11|2016
Switching behaviour "0 (stop):
The switching behaviour of the digital
input "0" can be changed (inverted)
by using the menu item "0".
"cL" means that the motor is
stopped at a closed contact.
"oP" means that the motor is
stopped at an open contact.
Resetting:
The motor is reset to the factory
setting when the "Info" button is
pressed for at least 10 seconds. The
motor stopd and "rESEt" is
displayed.
The pump current power
requirements are shown in watt (P
XXX) in the display when the "INFO"
button is pressed.
The control unit's display switches off
after three minutes without action.