Leak Testing Instructions
WARNING
!
This must be done before initial use, annually, and whenever any gas components
are replaced or serviced. Do not smoke while performing this test, and remove all
sources of ignition.
leak test using fire or flame. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Testing for a Gas Leak:
Ensure all control knobs are in the off position.
Turn on the fuel supply.
-For natural gas, turn the valve handle 1/4 turn to align with the gas flow.
STOP
-For L.P turn the cylinder valve knob counter clockwise one full rotation.
Brush or spray a half-and-half solution of liquid soap and water onto all joints and
connections of the regulator, hose, manifolds and valves.
Bubbles will indicate a gas leak. IMMEDIATELY turn off the gas supply.
See next page (28) for "Fixing a Gas Leak".
See Leak Testing Diagram for areas to check.
Leak Testing Diagram
Natural Gas
www.newageproducts.com
Never conduct a
50% WATER
50% LIQUID
SOAP
Spray
or
Brush
27