Télécharger Imprimer la page

BOMANN CL 6044 QC CB Mode D'emploi page 83

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
• Before connecting the pipes, decide where you want to place the
exterior unit and take care to ensure that there is enough room in the
location you have chosen for maintenance work to be performed at a
later time. (Observe the minimum distances)
• Put the protective caps (included in delivery) on the stand and fasten
these in the appropriate places.
• Use exceptionally sturdy screws / bolt anchors and bear in mind also
the weight of the appliance, in order to prevent vibrations caused by
operation from loosening the connection over time. The unit must be
installed in accordance with the applicable safety regulations.
Condensed Water Drain Pipe for the Exterior Unit
Condensed water and ice which build up in the exterior unit due to heat
generation can be drained by means of the condensed water pipe.
1. Fasten the supports for the condensed water drain pipe in the 25 mm
opening designed therefor.
2. Connect the supports for the condensed water drain pipe to the con-
densed water pipe and ensure the flow is properly controlled in order
to avoid moisture damage.
Electrical Connection (Exterior Unit)
Remove the connector cover (15) on the right side of the appliance. The
associated diagram can be found on the rear side. See diagram.
1. Connect the power supply cable for the interior unit to the terminal
strip.
2. Carefully attach the power supply cable for the exterior unit using the
cable connecting clamps.
3. Make sure that the cables have been properly attached. Be sure that
the grounding has been correctly installed.
4. Place the protective cover back on the appliance.
CAUTION:
All electrical works must be performed by a certified professional elec-
trician or specialist electronics company. Improper installation shall
result in expiry of the warranty.
Connection, Filling and Start-up Procedure
The coolant pipes are not filled, and this must be done before use.
The filling procedure may only be carried out by a certified specialist
company. For any further installation requirements, please contact the
appropriate specialist company.
Design model / Cooling capacity (Btu / h)
Cooling pipe diameter a)
Cooling pipe diameter b)
Standard cooling pipe length
Maximum distance between interior and exterior unit
Additional refrigerant charge
Maximum distance between interior and exterior unit
Cooling agent *
*) Additional information can be found on the information plate on the exterior unit.
CL6044CB_IM
Installation of the Exterior Unit
• The air conditioning unit must be installed and connected by a certi-
fied refrigeration and air conditioning company. Improper installation
shall result in expiry of the warranty.
• Operating the appliance without filling with coolant can cause
damage!
• Is the power switch functioning properly?
• Does the ventilator work?
• Do the operating modes function normally?
• Can temperature and time be accurately adjusted?
• Do all lamps light up in normal fashion?
• Are the airflow flaps functioning properly?
• Is the condensed water pipe functioning normally?
All of the steps described above must be performed by a certified
refrigeration and air conditioning company. Improper implementation
shall result in expiry of the warranty.
• Can unusual noises or vibrations be detected during operation?
• Is the cooling agent leaking?
NOTE:
The electronic control system will only start the compressor three
minutes after the unit is switched on.
All of the steps described above must be performed by a certified
refrigeration and air conditioning company. Improper implementation
shall result in expiry of the warranty.
Installation Information
Installation Instructions – Installation Information
1 / 4" 6
3 / 8" 9,52
20 g / m
5 m (15 m)
CAUTION:
Testing the Interior Unit
CAUTION:
Testing the Exterior Unit
CAUTION:
9k
12k
1 / 4" 6
1 / 2" 12
5 m
5 m
15 m
15 m
20 g / m
5 m (15 m)
R32
R32
15 / 18k
1 / 4" 6
1 / 2" 12
5 m
15 m
30 g / m
5 m (15 m)
R32
83
17.12.20

Publicité

loading