Télécharger Imprimer la page

BOMANN CL 6044 QC CB Mode D'emploi page 82

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
It is extremely important that the condensed water pipe for the interior
unit be installed in correct fashion.
1. Lay the drain hose below the pipe and make sure there are no dips or
recesses.
2. The drain hose must be inclined downwards in order to facilitate the
flow of the condensed water.
3. Do not bend or twist the drain hose. Do not allow it to protrude. Do
not immerse the end in water. If the pipe is connected to an exten-
sion, ensure the connection when inserting it into the interior unit.
4. If the cooling pipes are laid as shown at No. 3 in the chapter entitled
"Alignment of the Cooling Pipes", then the pipes, the connecting cable
for the exterior unit and the drain pipe for condensed water must be
secured to the rear side of the appliance using pipe couplings.
5. Insert the pipe connector in the corresponding appliance.
6. Press the connecting pipe down firmly into the air conditioning unit
and make sure the connection is tight.
CAUTION:
Avoid buckling during positioning and only permit these tasks to be
performed by a certified specialist companies!
Installation of the Interior Unit and Wall Bushing to the Outside
1. Using extreme care, lay the pipes, the connecting cable for the exte-
rior unit and the condensed water pipe towards the spot where they
are to be led through the wall to the outside.
2. Bind the condensed water pipes, the connecting cable for the exterior
unit and the condensed water pipe together using vinyl tape and
then cover everything tightly using insulating tape (not included in
delivery).
CAUTION:
• Ensure that the pipes are impermeably sealed to avoid moisture
damage and mildew build-up in the walling.
• Make sure all exposed tubular parts have been sufficiently isolated.
3. Drill a hole with a diameter of 57 mm and an incline / gradient of
5 - 7 mm. (Image 2)
NOTE:
Drill this with a slight incline of 5 - 7 mm toward the outside, to en-
sure that the condensed water is able to drain. In any case, make
sure that there is an incline over the entire length of the condensed
water pipe in the direction of the opening in the wall.
4. Insert the hole-cover.
5. Guide the insulated pipes, the connecting cable for the exterior unit
and the condensed water pipes through the opening in the wall.
NOTE:
After installing the pipes, seal the hole in the wall through which the
pipes have been passed so that it is airtight as well as watertight.
82
CL6044CB_IM
Connecting the Condensed Water Pipe for the Interior Unit
6. Fasten the interior unit securely to the upper part of the wall mounting
plate.
7. Press the lower part of the interior unit firmly against the wall mount-
ing plate until it rests firmly.
17.12.20

Publicité

loading