3. Remove the wall mount by releasing it from the holder.
4. Drill holes at least 32 mm deep in a solid wall in order to fasten the
plate.
5. Place the plastic dowels in the hole.
6. Fasten the mounting plate to the wall using the screws included.
7. Ensure that the mounting plate is screwed firmly in place.
Alignment of the Cooling Pipes
CAUTION:
The air conditioning unit must be installed and connected by a certi-
fied refrigeration and air conditioning company. Improper installation
shall result in expiry of the warranty.
The cooling pipes can be laid in 3 directions as depicted in accordance
with the numbers in the illustration. If the piping is placed in accordance
with options 1 or 3, then you must use a cutter to carefully cut a notch in
the side of the interior unit along the seam.
Guide the connection pipes in the direction of the opening in the wall
and bind the cooling pipes, the condensed water piping and the power
cable together using vinyl tape and always ensure impermeable insu-
lation so that no liquids, water vapour or condensate are permitted to
form and e. g. penetrate the wall. This will prevent the accumulation of
moisture as well as the formation of mildew. Ensure that the condensed
water pipe is placed on a gentle incline so that the water flow is not
obstructed.
CAUTION:
Ensure that the pipes are impermeably sealed to avoid moisture dam-
age and mildew build-up in the walling.
CL6044CB_IM
Unrolling the Cooling Pipes
• If the pipes are bent or pulled too frequently, they will become rigid.
Do not bend the pipes more than three times.
• Carefully unroll the pipes as shown in diagram A. Avoid buckling.
CAUTION:
Do not pull the pipe apart as shown in diagram B. Instead, unroll it
carefully.