ATEX Certificate
NMI Certificate
* At room temperature and stable environmental conditions without vibration and draft, with automated weight
placement.
2.2.2 Physical Dimensions
PJA434x / PJA439x Dimensions
A, optional
B
C, optional
D
E
F
2.3 Application Area
This product is approved for use in hazardous area Zones 1, 21.
2.4 Ambient Conditions
The product may only be operated accurately in the range of -10°C to +40°C / 14°F to 104°F, 10% - 95%
relative humidity, no condensing.
Fast temperature changes must be avoided because it will cause condensation in the electronics. During
acclimatization the weighing system must be switched off.
Consult METTLER TOLEDO for information about using the product in a chemical environment.
2.5 Further Document
Two documents named "Quck Guide" and "User Manual" are available for this product.
The Quick Guide is printed and delivered with the product.
The User Manual (available at www.mt.com) contains a full description of the product and its use.
Pallet Truck Scale
Optional
Dekra 13 ATEX 0044 X
II 2 G Ex ib IIC T4 Gb; II 2D Ex ib IIIC T135°C Db, -10°C ≤ Ta ≤
+40°C (PJA43*-IND226x)
II 2 G Ex ib IIC T4 Gb; II 2D Ex tb [ib] IIIC T60°C Db, -10°C ≤
Ta ≤ +40°C (PJA43*-IND256x)
II 2 G Ex ib IIB T4 Gb; II 2D Ex tb [ib] IIIC T60°C Db, -10°C ≤
Ta ≤ +40°C (PJA43*-IND256xW)
Optional
NMI Type Approval (T5920)
Fork Length
Fork Width
Lowered Fork Height
Maximum Fork Height
Width Over Forks
Height to Top Terminal
x
x
-
x
1150 / 950 / 1400 mm
160 mm
90 / 85 mm
200 mm
550 / 690 mm
1225 mm
Introductions