SCHÉMA DE FONCTIONNEMENT - CONTROL BOARD SORTIE AIR CHAUD CHAMBRE DE COMBUSTION HOT AIR OUTFLOW COMBUSTION CHAMBER CHEMINEE BRULEUR CHIMNEY BURNER VENTILATEUR REFROIDISSEMENT BOITIER THERMOSTATS F + L1 + L2 COOLING FAN THERMOSTATS F + L1+ L2 BOX L-L 230.04-BM 3 / 68...
Page 3
TABLEAU DE COMMANDE - CONTROL PANEL PRISE POUR BOITIER THERMOSTATS F + L1 + L2 THERMOSTAT DE SECURITE A REARMEMENT MANUEL, L2 INTERRUPTEUR CHAUFFAGE-VENTILATION SOCKET FOR THERMOSTATS F + L1+ L2 BOX LIMIT THERMOSTAT WITH MANUAL RESTART, L2 HEATING-VENTILATION SWITCH PRESSE-CÂBLES POUR CÂBLE D'ALIMENTATION TÉMOIN BLOCAGE VENTILATEUR (uniquement pour modèles triphasés) TEMOIN TENSION...
Page 4
IMPORTANT Avant toute utilisation du générateur, nous vous prions de lire attentivement toutes les instructions pour l'emploi mentionnées ciaprès et d'en suivre scrupuleusement les indications. Le constructeur n'est pas responsable des dommages aux personnes et/ou aux biens dus à une utilisation impropre de l'appareil. Ce livret d'utilisation et d'entretien est partie intégrante de l'appareil.
Page 5
3. CONSEILS D'ORDRE GÉNÉRAL • ou verticale L'installation, le réglage et l'utilisation du générateur d'air chaud doivent être accomplis dans le respect de toutes les normes et des lois nationales et locales en vigueur en matière d’utilisation de la machine. Il est conseillé...
Page 6
Attention 4.4. BRANCHEMENT À LIGNE D'ALIMENTATION COMBUSTIBLE La machine est dotée d'un câble d'alimentation provisoire, utilisé pour le contrôle du fonctionnement. Attention Les prescriptions d'installation, de réglage et d'utilisation visées par les réglementations régionales et/ou nationales Attention concernant l'emploi du générateur d'air chaud doivent Le câble d'alimentation provisoire doit être retiré...
Page 7
minimum 1 m) ; 4.7. PREMIÈRE MISE MARCHE RÉGLAGE COMBUSTION • les coudes et les sections réduites doivent être évités ; • toujours prévoir un terminal anti-refoulement pour éviter la chute Attention d’eau de pluie et empêcher le refoulement des fumées à cause du La première mise en marche doit toujours être exécutée vent ;...
Page 8
Attention En mode H+V, le ventilateur fonctionne en continu même Intervention Entretien périodique lorsque le brûleur s'éteint parce que la température ambiante est atteinte. Attention En mode H, le ventilateur ne fonctionne que lorsque la chambre de combustion est suffisamment chaude. De ce fait, lorsque la température ambiante est atteinte, le brûleur s'éteint et le ventilateur ne fonctionne que jusqu'au Contrôle du générateur d'air chaud...
Page 9
suit : de suie peut dépendre d'un tirage défectueux du conduit de cheminée, de la mauvaise qualité du combustible, du mauvais • Retirer les vis de fixation du groupe ventilateur et déposer le groupe ventilateur. réglage du brûleur ou de l'alternance plus ou moins fréquente des •...
Page 10
ANOMALIE DE FONCTIONNEMENT CAUSE SOLUTION • Vérifier le fonctionnement et la position de • L'appareil ne démarre pas : l'interrupteur. • Manque d'alimentation électrique • Vérifier les caractéristiques du réseau électrique • Vérifier les branchements électriques le témoin est éteint •...
Page 11
IMPORTANT Before using the space heater, carefully read all of the instructions and follow them scrupulously. The manufacturer cannot be held responsible for damage to persons and/or property caused by improper use of the equipment. This instruction manual is an integral part of the equipment and must therefore be stored carefully and passed on with the unit in the event of a change of ownership.
Page 12
heater has enough air to function properly; • The heater must be near a chimney or chimney flue and an electrical panel conforming to declared specifications; • Check the heater before switching it on and at regular intervals during its use; •...
Page 13
• Connect the thermostat electrical cable to terminals 2 and 3 of the thermostat plug (c). • Close the plug again and plug it back into the panel. Warning Never attempt to switch the heater on or off by connecting the room thermostat (or other control devices) to the electrical power line.
Page 14
temperatures and that ensures the tube remains airtight. Warning Upon completing the aforementioned operations, the declaration assembly installation penultimate page of this manual is to be completed in full and signed. 5. OPERATING INSTRUCTIONS 5.1. START To start the heater: •...
Page 15
6. MAINTENANCE • Make sure the air inlet is not obstructed. Warning • Pipes, connectors and joints: All of the operations described in this section must be • Clean with a cloth. performed by professionally qualified personnel only. • External body: •...
Page 16
Clean with compressed air or, if necessary, with a metal brush to remove any deposited soot and combustion residues. • on the burner the blocking signal following intervention by the burner's Warning flame control box. After any technical work, always check that the heater works correctly.
Page 17
FAULT CAUSE REMEDY • The heater does not start: • Check functioning and position of switch • Check the mains • No power supply • Check power connections • Check fuse lamp is off • Switch (a) in wrong position •...
Page 21
SCHEMA ELECTRIQUE WIRING DIAGRAM MOTORE VENTILATORE RESISTENZA ANTICONDENSA MOTEUR VENTILATEUR RÉSISTANCE ANTICONDENSATION VENTILATORMOTOR KONDENSWASSERHEIZUNG FAN MOTOR ANTI-CONDENSATION RESISTANCE MOTOR VENTILADOR RESISTENCIA ANTICONDENSACIÓN ДВИГАТЕЛЬ ВЕНТИЛЯТОРА СОПРОТИВЛЕНИЕ ПРОТИВ ОБРАЗОВАНИЯ КОНДЕНСАТА TERMOSTATO VENTILATORE TELERUTTORE VENTILATORE THERMOSTAT VENTILATEUR TELERUPTEUR VENTILATEUR LUFTREGLER SCHÜTZ VENTILATOR FAN THERMOSTAT FANS TELE-CONTACTOR TERMOSTATO VENTILADOR TELERUPTOR VENTILADOR...
Page 22
CARACTERISTIQUES TECHNIQUES FARM 115 FARM 155 FARM 190 FARM 240 FARM 95 TECHNICAL SPECIFICATIONS Protection IP - IP protection IP X4D IP X4D IP X4D IP X4D IP X4D Type B23P B23P B23P B23P B23P Combustibile DIESEL #2 DIESEL #2 DIESEL #2 DIESEL #2 DIESEL #2...
Page 23
FARM 95 FARM 115 FARM 155 FARM 190 FARM 240 ENTREE AIR - AIR INLET Diamètre du tuyau - Tube diameter [mm] Tuyau flexible non perforé Flexible tube without holes Longueur maxi - Maximum length SORTIE AIR - AIR OUTLET Diamètre du tuyau - Tube diameter [mm] Tuyau flexible non perforé...
Page 24
DÉCLARATION D'ASSEMBLAGE ET D'INSTALLATION MONTAGE- DECLARATION OF ASSEMBLY AND INSTALLATION Le générateur d'air chaud Modèle / Numéro de série The space heater, Model / Serial number 65700201 65700300 ÷ Équipé d'un moteur – ventilateur, tableau électrique et d'un brûleur Fitted with a motor-fan, electrical panel and burner a été...
Page 34
FARM 240 L-D460.01-SO Da N.° serie Von Masch. Nr. From S/N PL 05/16 De No. Serie 65900101 LEGENDA DESCRIZIONE DESCRIPTION BESCHREIBUNG DESCRIPTION G04345 Pannello Panneau Verkleidungsplatte Panel G04346 Pannello Panneau Verkleidungsplatte Panel G04347 Telaio Châssis Gestell Frame G04289 Staffa Étrier Bügel Stirrup G04348...
Page 35
CARNET D’ENTRETIEN TYPE :…………………………………………………………………………………………………. N° DE SERIE:…………………………………………………………………………………………. PIECES ENTRETIEN DATE OBSERVATION CHANGEES REGULIER ANNUEL...