Minimum: The system operates at minimum speed, irrespective of the number of zones.
•
Wireless module. It activates/deactivates the wireless association module of the system.
•
Information (only for Think thermostats). Displays information about:
-
Zone: Firmware, zone, association, actuator o communications status.
ES
-
System: Firmware, configuration and information about the controllers.
EN
-
Devices: Displays what elements are connected to the system.
•
Reset system (only available for master thermostat Blueface). Resets the system and returns to factory settings. To
FR
reconfigure the thermostats, please check Initial setup).
IT
ZONE PARAMETERS
•
Associated outputs. It displays and allows you to select the control outputs associated with the thermostat.
PT
•
Thermostat settings. Use this parameter to define the thermostat as Master or Zone.
DE
*Note: It cannot be configured as Master if there is already another Master thermostat.
•
Use mode. The thermostats can be set in Basic or Advanced mode. They are set in advanced mode by default. These
are the parameters you can control in basic mode:
-
On/Off.
-
Set-point temperature.
-
Fan Speed
If you need to reset the thermostat to advanced mode, access the advanced configuration menu and then activate the
advanced use mode.
•
Control stages. This parameter is used to configure both cooling and heating stages in a single zone or in all the
zones. These are the features to be configured:
-
Air: It activates the heating/cooling air in the zone.
-
Off: It deactivates the cooling/heating stage in the zone.
•
Offset. Allows you to correct ambient temperature that is measured in the various areas or in all of them, due to
deviations by sources of heat/cold nearby, with a correction factor between - 2,5ºC and 2,5ºC in steps of 0,5ºC. It is in
0ºC by default.
•
Reset thermostat (not available in remote zones). Resets the thermostat returning to Setup menu (see section Initial
configuration).
44