Télécharger Imprimer la page

Sovelor SP40 Manuel D'utilisation Et De Maintenance page 26

Publicité

4.1. INSTALLATION ON FLOOR
The space heater may be installed on the floor in a stable position or
close to lateral wall fo the room
Warning
At least one of the two side air inlet panel (m) shall be kept
open to allow air entering.
Warning
If necessary, the panel (n) with the safety thermostat must
be moved to the opposite side: in this case, return to
manufacturer or distributor for assembly procedure taking
care to reposition the safety thermostat correctly.
The minimum distance from surrounding walls, floor and/or ceiling
must always be at least 1 metre.
4.2. POWER CONNECTIONS
Warning
The power line must be earthed and fitted with a residual
current circuit breaker.
The power cable must be connected to a panel fitted with a
cut-out.
Before switching on the heater and, therefore, before plugging it into
the electrical power supply, check that the power supply
specifications are the same as those stated on the identification
plate.
Any room thermostat or other accessories (such as a timer) are
connected to the system by connecting the electrical cable to the
thermostat plug (h):
• Take the plug (h) out of the electrical panel, open the plug and
remove the jumper between terminals 2 and 3.
• Connect the thermostat electrical cable to terminals 2 and 3 of the
thermostat plug (h).
• Close the plug again and plug it back into the panel.
Warning
Never attempt to switch the heater on or off by connecting
the room thermostat (or other control devices) to the
electrical power line.
The installation and connection of all the other accessories are
described in the specific instructions included with each accessory,
together with operating instructions.
The electrical diagram shown in this manual refers to the electrical
connection only.
4.3. CONNECTION TO HOT AIR DELIVERY DUCTS
The space heater is set to operate with direct distribution of air. In
such case a proper air outlet, chosen by list of available accessories
on catalogue, shall be used:
L-L 278.00-SO
EN
n
Revolving heads
m
Nevertheless, it can be connected to appropriately sized air
distribution channels, if required, with maximum diameter and length
as shown in the "TECHNICAL SPECIFICATION TABLE."
4.4. MOUNTING THE DIESEL BURNER
4.4.1. RIELLO BURNER
• Open the box containing the diesel burner, remove it and keep the
two stickers with lot number for later use;
• Consult the user manual of the burner; and fit the burner fixing
screw onto the burner plate according to the instructions
• Secure the burner plate to the machine by using the 4xM8 screws
and the D8 x D24 washers;
• Insert the burner and fix it to the plate by tightening the nut supplied
onto the screw G;
• Locate the black cable with 7-pin Wieland plug running out of the
electrical panel and insert the plug into the socket H on the burner;
H
• Remove the burner cover and secure the two hoses to the fittings
of the fuel pump already in place;
Warning
The diesel burner is factory-set according to the
parameters shown on the "TECHNICAL SPECIFICATIONS
TABLE" for 50Hz models.
For 60Hz models, you have to change the combustion air
setting as shown on the Table.
Multiple outlet head
G
26 / 52

Publicité

loading

Ce manuel est également adapté pour:

Sp75