RS 350 - 450 - 550 M / MW PRO
Failure
Fan is not operating
Machine operates noisily
Unstable and / or non-adjustable
welding current
Heater outlet is not operating
4.4 Fuses
F1
Fuse
F2
F3
F4
4.5 Error Codes
Error Code
Error
E01
Thermal
Protection
Temperature Sensor
E05
Reading Error
www.magmaweld.com
• The fuse has blown
• Fan motor failure
• Contactor failure
• Diode group failure
• The fuse has blown
10 A
Amperage
1 A
1 A
1 A
• The uptime of your machine may have
been exceeded
• Fan may not be working
• The front of the air inlet-outlet ducts
may be blocked
• The machine working environment
may be too hot or stuffy
• There may be a hardware error
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
• Check the fuse
Reason
• Contact the authorized service
• Contact the authorized service
• Contact the authorized service
• Check the fuse. Contact the
Fast
Feature
Delayed
Fast
Fast
• Allow the machine to cool down by
Cause
• If the problem continues, contact the
• Check visually whether the fan is
• If the problem continues, contact the
• Open the front of the air ducts
• If the problem continues, contact the
• Make sure that the working
• If the problem continues, contact the
• Contact the authorized service
Maintenance and Service
Solution
authorized service
Motor and Card of the Wire Feeder
Protected Circuir
Cooler Fan
CO2 Heater
Card of Voltmeter / Ampermeter
Solution
waiting for a while. If the fault
disappears, try to use the machine at
lower amperage values
authorized service
working or not
authorized service
authorized service
environment of the machine is not
excessively hot or stuffy
authorized service
33