CAUTION!
Electrostatic sensitive components/modules!
The device contains electronic components which react
sensitively to electrostatic discharge (ESD). Contact with
electrostatically charged persons or objects is hazardous
to these components. In the worst case scenario they will
be destroyed immediately or will fail after start-up.
Observe the requirements in accordance with EN 100015
- 1 to minimise or avoid the possibility of damage caused
by sudden electrostatic discharge.
Also ensure that electronic components do not come into
contact with a nearby power supply.
english
8
Warranty Terms
This document does not offer any form of warranty. Please
refer to our general terms of sales and business. The war-
ranty is only valid if the device socket booster Type 2511 is
used as intended in accordance with the specified operating
conditions.
Trademarks
The brands listed below are trademarks of the correspond-
ing companies / associations / organisations
®
Ultrason
BASF AG, Ludwigshafen
Information on the Internet
The operating instructions and data sheets for Type 2511
can be found on the Internet at:
www.burkert.com
Technical Data
type 2511
english
10
Manuals / Datasheets
GENERAL INFORMATION
Product Package
Check immediately upon receipt of delivery that the contents
are not damaged and that they correspond to the type and
quantity as indicated on the delivery note or packing list.
If there are any discrepancies, please contact us
immediately.
Germany
Contact address:
Bürkert Fluid Control Systems
Sales Center
Chr.-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. : 07940 - 10 111
Fax: 07940 - 10 448
E-mail: info@de.burkert.com
International
Contact addresses can be found on the final pages of
these operating instructions.
And also on the internet at:
www.burkert.com
Bürkert
DESIGN AND FUNCTION
The device socket booster Type 2511 consists of a poly-
amide housing with integrated electronics and a connector
diagram in accordance with DIN EN175301-803 (previously
DIN 43650 Form A).
The device socket is used exclusively to control DC
coils. The built-in rectifier makes it possible to oper-
ate with DC or alternating current.
Function
The device socket booster Type 2511 is used to increase the
power of solenoid valves. The switchable pressure range can
therefore be extended. Furthermore, the power consumption
and the coil temperature, e.g. during continuous operation,
can be reduced considerably. Appropriate solenoid coils must
be individually designed for the particular valve and power
supply. Please contact your Bürkert sales office.
The high pick-up power is generated by overexcitation. When
the valve is actuated, the electronics drop to a low holding
power. The electronics in the 24V DC model are able to
detect the switching point of the valve and automatically
change to the reduced power phase after switching, while the
overexcitation phase of models operating at a different power
supply voltage is a constant 400ms.