Télécharger Imprimer la page

STEINEL PROFESSIONAL IR Quattro COM1-WR Manuel page 8

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Installer:
This high-quality product has
been manufactured, tested and
packaged with the assurance of
your complete satisfaction.
Safety Warnings
í Disconnect the power supply
before attempting any work
on the sensor!
í Before installation, make sure
that power has been
switched off at the breaker
and check that the circuit is
dead with a voltage tester.
Assembly/Installation
For indoor use only.
Sensor and load module come
ready assembled and must
be plugged together after
mounting the load module
and setting the potentio-
meters/dip switches.
System Components
Load module
Sensor module
Sensor control plate
Sensor DIP switch settings
(1) Normal / Test mode
(2) Manual 'ON' / Automatic
'ON' mode
(3) Momentary / Maintained
switch option
(4) 'ON' only / 'ON'&'OFF'
manual switching
(5) Constant light level DIM
control option
IR Quattro COM-WR_USA_03-07-13_ENU-FRA.indd 8
R Quattro COM-WR_USA_03-07-13_ENU-FRA.indd 8
Please read all of the instructions
before installation. This will help
you to be familiarized with all
the features and options avail-
able to you with these devices.
í Installing the sensor involves
work on the mains power
supply. This work must there-
fore be carried out profes-
sionally in accordance with
the applicable national wir-
ing regulations and electrical
operating conditions.
(see chart on page 2)
The sensor and load module
must then be secured together
with the locking mechanism
using a screwdriver if necessary.
Light level setting
Occupancy time
delay setting
Switching output 1
HVAC stay-'ON' time
Switching output 2
HVAC switch-'ON' delay
Switching output 2
Reach setting
k
1 0
COM1-WR Wiring
.1
k
1 0
COM1-WR Multiple Sensor
.2
Wiring
- 8 -
This will also assist you to mini-
mize installation time and pro-
vide maximum energy savings
and trouble-free operation.
í Control output DIM-24
(1-10 V) must only be used
for connecting electronic
ballasts with an electrically
isolated 10V dimming
control input.
Accessories:
- WGC Wire Guard Cage
,
- RC 3 Service Remote
- RC 4 User Remote
k
1 1
COM1-24 Wiring
.1
k
1 1
COM2-24 Wiring
.2
k
1 1
COM2-24 Multiple Sensor
.3
Wiring
k
1 1
DIM-24 Wiring
.4
k
1 1
DIM-24 Multiple Sensor
.5
Wiring
Locking mechanism
Assembly / Installation /
Dimensional Drawings
Stay 'ON' time DIM before
'OFF' option
04.07.13 14:
04.07.13 14:

Publicité

loading