Télécharger Imprimer la page

STEINEL PROFESSIONAL IR Quattro COM1-WR Manuel page 22

Publicité

Les langues disponibles

Les langues disponibles

COM2-24
Potentiometer
Stay-'ON' time for switching output 2 HVAC
Setting 1 sec. – 2 hr.
• Turned fully clockwise: max
• Turned fully counterclockwise: min
Potentiometer
Switch-'ON' delay for switching output 2 HVAC
• Setting 0 sec. – 10 min.
• Turned fully clockwise:
Auto-HVAC mode
• Turned fully counterclockwise:
0 sec. (OFF)
DIM-24
Potentiometer
Stay 'ON' time DIM before 'OFF' option
Provides basic illumination for the
selected stay-'ON' time when am-
bient light falls below the selected
brightness threshold that is set.
This can be dimmed to 10% of
maximum light intensity. As soon
as a person is detected, the sensor
switches either to 100% light
intensity (constant-lighting
Reach Adjustment
Potentiometer
Adjusts reach to specific
requirements.
IR Quattro COM-WR_USA_03-07-13_ENU-FRA.indd 22
R Quattro COM-WR_USA_03-07-13_ENU-FRA.indd 22
Turning the potentiometer to the
"Auto-HVAC mode" setting reduces
the sensitivity of the "Presence"
switching output. The contact only
closes after surveying the activity
of the space and then, signaling
controller 'OFF') or adjusts to the
preselected brightness level
(constant-lighting controller 'ON').
When no movement is detected
and the occupancy time setting
has elapsed , the sensor dims
light levels back to basic bright-
ness after the stay 'ON' time
(1 min. - 30 min.) has expired or
See table on pages 4-5 showing
Technical Specifications for
selecting settings to suit specific
requirements.
- 22 -
with a high degree of certainty that
multiple persons are present. The
stay-'ON'- time remains active. The
switch-'ON' delay is inactivated.
the daylight level exceeds the
selected level of brightness.
If the occupancy time delay setting
is greater than the stay on time
DIM before 'OFF' setting
light will not dim before turning
'OFF' .
the
04.07.13 14:
04.07.13 14:

Publicité