Dimplex SIW 6TES Instructions D'installation Et D'utilisation page 32

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SIW 6TES - SIW 11TES
6.8
Power consumption of compressor protection (per compressor)W
6.9
Power consumption of heat circulating pump
6.10 Power consumption brine circulating pump
6.11 Electrical pipe heater (2nd heat generator)
7
Complies with the European safety regulations
8
Additional model features
8.1
Water in device is protected against freezing
8.2
Max. operating overpressure (heat source/heat sink)
9
Domestic hot water cylinders
Material
9.1
cylinder volume
9.2
nominal volumen
9.3
Max. operating pressure
9.4
Heat exchanger area
9.5
Heat loss at 50°C cylinder temperature
20°C room temperature
9.6
Draw-off rate (without re-heating)
3
10
Heat output / COP
1. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
2. Please note that additional space is required for pipe connections, operation and maintenance.
3. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and operation
can be found in the respective sections of the installation and operating instructions. The specified values have the following meaning, e.g. B0 / W35: Heat source temperature
0 °C and heating water flow temperature 35 °C.
4. Condition as received 6kW.
5. See CE declaration of conformity
6. The heat circulating pump and the heat pump manager must always be ready for operation.
7. Mixed water withdrawal temperature 38 °C and cylinder temperature 45 °C.
EN-14
W
W
kW
6
bar
in litres
in litres
bar
kW/h24h
7
Litres
at B-5 / W45
kW / ---
at B0 / W55
kW / ---
at B0 / W45
kW / ---
at B0 / W35
kW / ---
452236.66.05 · FD 9606
--
--
Max. 70
Max. 70
Max. 87
Max. 87
4
2.4 or 6
2.4 or 6
5
5
Yes
Yes
3,0
3,0
Enamelled steel com-
Enamelled steel com-
plying with DIN 4753
plying with DIN 4753
170
170
156
156
6
6
2,1
2,1
0,69
0,69
213
213
EN 14511
EN 14511
4,9 / 3,2
6,4 / 3,3
5,4 / 2,9
7,1 / 2,9
5,6 / 3,6
7,3 / 3,7
5,9 / 4,7
7,8 / 4,8
--
Max. 70
Max. 87
4
4
2.4 or 6
5
Yes
3,0
Enamelled steel com-
plying with DIN 4753
170
156
6
2,1
0,69
213
EN 14511
8,7 / 3,3
9,5 / 2,9
9,9 / 3,8
10,5 / 5,0
www.dimplex.de

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Siw 8tesSiw 11tes

Table des Matières