EXPERT SERIES / EXPERT SERİSİ
• Unit the water cooling unit is used to cool the torch It is a closed circuit system consisting of radiator, fan,

2.3.4 Water Cooling Unit (for MW Models)

pump coolant reservoir.
• Connect the cold (blue) water hose to the cold water outlet on the water cooling system, and the hot (red)
water hose to the hot water inlet on the water cooling system.
• Magmaweld welding machines come with Magmaweld coolant, which is produced to give the best
performance. In case of lack of coolant, open the coolant reservoir cap and add Magmaweld coolant suitable
for the temperature of the working environment. The coolant must be within the minimum and maximum
values shown on the front panel of the unit.
• Different coolant or water should not be added. Different liquid additives can cause chemical reactions or
different problems.
• Magmaweld is not responsible for the risks that may arise in case of adding different liquids. All warranty
provisions will be void if different coolant or water is added to the Magmaweld coolant.
• If it is desired to use a different brand of coolant, the inside of the coolant tank should be completely empty
and there should be no residue or liquid in it.
• It is not suitable to use the water-cooling units with welding machines other than manufactured by Magma
Mekatronik Makine ve Sanayi Ticaret A.Ş. Water cooling units cannot be operated with external supply.
• For easy transport of machines with hose package of 10 meters or longer, the wire feed unit and the interim

2.3.5 Connection of Interconnection Hose Package

package have been designed to be detachable. Both ends of the long hose packages are the same and the
connections on the machine front must be made with the connectors and sockets on the back of the wire
feeder.
• If interconnection hose package is 10 meters or longer, connect the wire feed unit with the hose package as
follows.
c
b
a
Dirty and lime (hard) waters reduce the operating life of the torch and the pump.
If the coolant is below the minimum value, there is a possibility of damage and malfunction
• There are 2 leds in front of the machine: The power led will light as soon as the machine is activated and the
for the pump and torch.
water-cooling unit led will light when the water unit is activated.
• As soon as the machine starts welding, the water circulation will start and after the welding is completed, the
water-cooling unit led will remain on during the time set in the menu. In case of any air inlet or problem, the
water will not be recirculated.
www.magmaweld.com
Figure 4 : Long Harness Connections
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
Installation
c
b
a
d
e
19