30
Operation
PAGE 7
EN
It operates as a percentage of the main current. The minimum and maximum current range to which the
A) D.PULSE CURRENT ADJ. (DOUBLE PULSE CURRENT ADJUSTMENT)
double pulse will go will be determined.
• %5-50
Setting Range
The display shows both the setting in terms of percentage and the maximum and minimum current values.
For Example;
D. Pulse Current Adj.
%10
129 / 106
When double pulse method is selected, the time of maximum and minimum current will be determined as
b) D.PULSE TIME ADJ. (DOUBLE PULSE TIME ADJUSTMENT)
a percentage.
• %20-80
Setting Range
The % value displayed on the screen is the time at which the maximum current is displayed.
For Example;
D. Pulse Current Adj.
%10
129 / 106
D. Pulse Time Adj.
%20
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
Let the current be set to 118 A. If the 10% current setting range is selected, the
value will be read as 129/106. That is, 10% more of 118 and 10% less than 118
will be displayed on the screen.
Let the current be set to 118 A. If the 10% current setting range is selected, the
value will be read as 129/106. That is, 10% more of 118 and 10% less than 118
will be displayed on the screen. If the D. pulse time setting is set to 20%, it holds
129 A in 20% in the double pulse function and 106 A in 80%.