Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or the software re-
lease.
1 – Press the button <PG>, the display goes to the first menu, Parameters "PAR".
2 – With the <+> or <-> button, select the menu you want (PAR>LOG>RAD>NMAN>MACI>RES>AUTO>CODE).
3- Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 120s the control unit quits programming mode and switches off the display.
When the board is switched on, the software version is displayed for around 5 sec
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
The tables below describe the individual functions available in the control unit.
MENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Operating time, motor 1. The operating time is adjusted at normal speed during motor
1 opening and closing phases. See Paragraph "Adjustment of the gate leaf speed".
TM1
By setting the value to 0, the operation is performed with around 2 seconds of pick-up
and then the movement is carried on at reduced speed for the entire stroke.
Operating time, motor 2. The operating time is adjusted at normal speed during motor
2 opening and closing phases. See Paragraph "Adjustment of the gate leaf speed".
TM2
By setting the value to 0, the operation is performed with around 2 seconds of pick-up
and then the movement is carried on at reduced speed for the entire stroke.
The anti-crash device* (amperometric sensor) operation is adjusted in the opening
PMo1
phase, at normal speed - Motor 1.
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
PMC1
phase, at normal speed - Motor 1.
The anti-crash device* (amperometric sensor) operation is adjusted in the opening
PMo2
phase, at normal speed - Motor 2.
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
PMc2
phase, at normal speed - Motor 2.
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
Adjusts motor 1 speed during slowing phases. Value expressed in percentage of
SLD1
normal functioning speed.
Adjusts motor 2 speed during slowing phases. Value expressed in percentage of
SLD2
normal functioning speed.
Adjusts motor 1 speed during normal speed phase.
SpD1
Value expressed in percentage.
Adjusts motor 2 speed during normal speed phase.
SpD2
Value expressed in percentage.
The anti-crash device* (amperometric sensor) operation is adjusted in the opening
Pso1
phase, at reduced speed - Motor 1.
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
Psc1
phase, at reduced speed - Motor 1.
The anti-crash device* (amperometric sensor) operation is adjusted in the opening
Pso2
phase, at reduced speed - Motor 2.
The anti-crash device* (amperometric sensor) operation is adjusted in the closing
Psc2
phase, at reduced speed - Motor 2.
The intervention threshold of the anti-crashing device (Encoder) during the phase at
SeaU
normal speed is adjusted.*
0:Off-1:minimum sensitivity - 99: maximum sensitivity
14
TO ACCESS PROGRAMMING:
NOTES:
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
PARAMETERS (PAR)
FUNCTION
MIN-MAX-(Default)
MEMO
1-240-(40s)
0-99-(5s)
0-99-(5s)
1-99-(20%)**
1-99-(20%)**
1-99-(20%)**
1-99-(20%)**
0-15-(2s)
0-40-(3s)
30-70 (50%)
30-70 (50%)
30-99 (99%)
30-99 (99%)
1-99-(20%)**
1-99-(20%)**
1-99-(20%)**
1-99-(20%)**
0-99-(0%)