IMPORTANT: The control unit is equipped with the Autoset function to automatically set the main functioning values based on the type of
installation.
The AUTOSET function must be repeated at every function parameter change or upon change of automation conditions. See the AUTO
menu for further information.
Wire connections shown in Fig. 1 are described hereunder:
Terminal No.
Function
1-2
Motor 1
3-4
Motor 2
5-6
Flashing light
SCA/
9-10
PHOTO TEST/
2 CH
11-12
24 Vac/dc
13-25
COM/ENC+
14
SWO1/ENC1
15
SWC1
16
SWO2/ENC2
17
SWC2
18
PHOTO/BAR
19
PHOTC
20
STOP
23
PED
24
Step-by-Step
26
ENC-
31-32
Antenna
+ / -
24VAC/dc
C O N F I G U R A T I O N
U11
MEMORY
In case the motor is with Encoder and one wished to connect it to the control unit, carry out the connections indicated in Fig.2, in this case
the SWO1 and SWO2 inputs may not be used as Limit switch inputs.
It is not possible to use the Encoder and the closure Limit switch simultaneously.
Leave SWC1 and SWC2 shorted.
1) Cut-off power supply.
2) Manually release the wings, move them to approx. half-stroke and lock them again.
3) Reset power supply.
4) Send a step-by-step control signal by pressing the <-> push-button.
5) The leeaves must move in OPENING.
In case this does not happen, it is sufficient to invert among them the motor run wires. (1<>2 for M1 motor, and 3<>4 for M2 motor) and,
if used, the relative Limit switch inputs (14<>15 for M1 motor, and 16<>17 for M2 motor).
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting the desired
values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
The logic menu allows you to activate or deactivate a function, in the same way as setting a dip-switch.
HEADY 24 3B CONTROL UNIT
AUTOSET FUNCTION
WIRE DIAGRAM
Connection, motor 1: 24VDC 2.5A max
Connection, motor 2: 24VDC 2.55A max
Connection, flashing light 24VDC 15W max.
Normally Open, voltage-free contact, configurable as open gate indicator light, photocell test or
second radio channel (see Fig. 4).
For use as "Open gate indicator" the TEST1 and TEST2 logics must be OFF
For use as photocell test it is sufficient to activate one or both TEST logics and connect the
photocells as indicated in Fig.3.
Output, accessory power supply, 24VAC/0.5A max.
IMPORTANT: If the battery charger board is installed, the output (without mains power connected)
has a 24Vdc polarised voltage.
Make sure the devices are correctly connected (i.e. 11:+24Vdc / 12:-0Vdc).
Common for limit switch and all the command inlets or encoder power supply.
Motor 1 OPEN limit switch input (N.C. contact) or Motor 1 Encoder connection.
Motor 1 CLOSE limit switch input, (N.C. Contact)
Motor 2 OPEN limit switch input, (N.C. Contact) or Motor 2 Encoder connection.
Motor 2 CLOSE limit switch input, (N.C. Contact)
Input, photocell activated in both opening and closing phases
As an alternative, the PHOTO input can be used to connect a safety edge (see BAR logics).
Input, photocell activated in closing phase only (Normally closed contact)
Input, STOP push-button (Normally closed contact)
Input, pedestrian push-button (N.O. (Normally Open) contact). It controls the total opening,
motor 1.
Input, step-by-step push button (Normally open contact)
Input for GND Encoder connection (see Fig.2).
Connection to the built-in radio receiver card (31-signal/32-screen).
Input, 24VAC/24VDC power supply.
In case of use of plug batteries connect the battery charging card as indicated in the specific
installation instructions.
Extractable Eprom Memory. Contains all the control unit configurations (logics, parameters, etc.),
including the radiotransmitters. In case of faults it is possible to extract Eprom and insert it into
a different control unit, avoiding reprogramming.
ENCODER WIRING
TO CHECK CONNECTIONS