An optional accessory is available for control unit power supply in case of absence of power.
The kit is made up of a battery charging board and two 12V rechargeable batteries, fixing clamps, screws and wiring.
For further information, refer to the instructions supplied with the accessory.
SWO1
SWO2
SWC1
SWC2
P.P.
PED
PHOT
STOP
PHOT-C
Some messages that are displayed in case of function anomalies are listed as follows:
Obstacle error motor 1/anti-crushing
Amp1
Obstacle error motor 2/anti-crushing
Amp2
Error, encoder 1/detection of the obstacle
ENC1
Error, encoder 2/detection of the obstacle
ENC2
Motor 1 circuit checking error
Err1
Motor 2 circuit checking error
Err2
error/fault power circuit
Err3
PHOTO/BAR photocell checking error
Err4
PHOTC photocell checking error
Err5
Error active stop (during autoset)
Err7
Error active input (during autoset)
Err8
Motor thermal protection intervention
thrm
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal and
the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a specialised
company.
TECHNICAL DATA
Contol unit supply
Power supply
Output supply
Maximum motor current
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported
18
EMERGENCY BATTERY
DIAGNOSTICS
One segment of the display is linked to each input. In the event of failure it switches on ac-
cording to the following scheme.
N.C. inputs are represented by the vertical segments. N.O. inputs are represented by the
horizontal segments.
The control unit sees the message AMP1 or AMP2 in case of anti-crushing ammeter sensor
intervention.
ERROR MESSAGES
Check presence of obstacles on motor 1 leaf run
Check presence of obstacles on motor 2 leaf run
Check the correct connection of motor 1 encoder to the control unit, that
no obstacles are present along the gate stoke and the encoder operates
correctly.
Check the correct connection of motor 2 encoder to the control unit, that
no obstacles are present along the gate stoke and the encoder operates
correctly.
Check motor 1 connections
Check motor 2 connections
Request technical assistance and eventually replace control unit.
Check connections, PHOTO/BAR photocell alignment or presence of ob-
stacles.
Check connections, PHOTC photocell alignment or presence of obstacles.
In autoset phase, the STOP input has intervened.
In autoset phase a PP/Open/Close input has intervened.
Wait for motor cooling, in case reset does not take place, motor replacement
may be necessary
WASTE DISPOSAL
24 Vdc
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
1/2 motor 24Vdc
2.5+2.5 A
24Vdc 500mA max.
IP54
-20°C / +50°C
built in 433,92 MHz confgurabile (rolling-code or programmable + rolling-code)
64