Transport And Storage; Safety Measures - BEHA UNITEST TELARIS Fi/RCD Mode D'emploi

Masquer les pouces Voir aussi pour UNITEST TELARIS Fi/RCD:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Scope of Supply
1 pc UNITEST TELARIS Fi/RCD-Analyzer
1 pc 3 pole test lead
1 pc Test lead with mains plug
1 pc Croccodile clamps
3 pc Test probe
1 pc Protective Holster
1 pc Carrying Case
6 pcs Battery 1.5V, type IEC LR6 (Size AA)
1 pc Instruction manual

2.0 Transport and Storage

Please keep the original packaging for later trans-
port, e.g. for calibration. Any transport damage due
to faulty packaging will be excluded from warranty
claims.
In order to avoid instrument damage, we recom-
mend that batteries are removed when not using
the instrument over a certain period of time. How-
ever, should the instrument be contaminated by
leaking battery cells, you are kindly requested to re-
turn it to the factory for cleaning and inspection.
Instruments must be stored in dry and closed areas.
In the case of an instrument being transported in ex-
treme temperatures, a recovery time of at least 2
hours is required prior to instrument operation.

3.0 Safety Measures

The UNITEST Telaris FI/RCD Analyzer has been de-
signed and checked in accordance with the safety
regulations for Electronic test and Measurement In-
struments EN 61010 and IEC 61010, and left our
factory in a safe and perfect condition.
The instruction manual contains information
and references necessary for safe operation
and maintenance of the instrument.
The respective accident prevention regula-
tions established by the professional associa-
tion for electrical systems and equipment
must be strictly met at all times.
Transport and Storage / Safety Measures
In order to avoid electrical shock, the valid
safety and VDE regulations regarding exces-
sive contact voltages must receive the utmost
attention when working with voltages exceed-
ing 120V (60V) DC or 50V (25V)rms AC. The
values in brackets are valid for limited ranges
(as for example medicine and agriculture).
Measurements in dangerous proximity of
electrical installations are only to be executed
when instructed by a responsible electrical
specialist, and never alone.
If the operator's safety is no longer guaran-
teed, the instrument is to be put out of service
and protected against use. The safety can no
longer be guaranteed if the instrument (or
leads):
• shows obvious damage
• does not carry out the desired measurements
• has been stored for too long under un-
favourableconditions
• has been subjected to mechanical stress dur-
ing transport.
Avoid any heating up of the instrument by di-
rect sunlight to ensure perfect functioning and
long instrument life.
Prior to usage, inspect the instrument and test
leads for external damage. Prior to any opera-
tion, ensure that connecting leads used and in-
struments are in perfect condition.
The instrument may only be used within the
operating ranges as specified in the technical
data section.
33

Publicité

Table des Matières
loading

Table des Matières